The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Quantitative 3D-OCT motion correction with tilt and illumination correction, robust similarity measure and regularization
Open accessAbstract
Variability in illumination, signal quality, tilt and the amount of motion pose challenges for post-processing based 3D-OCT motion correction algorithms. We present an advanced 3D-OCT motion correction algorithm using image registration and orthogonal raster scan patterns aimed at addressing these challenges. An intensity similarity measure using the pseudo Huber norm and a regularization scheme based on a pseudo L0.5 norm are introduced. A two-stage registration approach was developed. In the first stage, only axial motion and axial tilt are coarsely corrected. This result is then used as the starting point for a second stage full optimization. In preprocessing, a bias field estimation based approach to correct illumination differences in the input volumes is employed. Quantitative evaluation was performed using a large set of data acquired from 73 healthy and glaucomatous eyes using SD-OCT systems. OCT volumes of both the optic nerve head and the macula region acquired with three independent orthogonal volume pairs for each location were used to assess reproducibility. The advanced motion correction algorithm using the techniques presented in this paper was compared to a basic algorithm corresponding to an earlier version and to performing no motion correction. Errors in segmentation-based measures such as layer positions, retinal and nerve fiber thickness, as well as the blood vessel pattern were evaluated. The quantitative results consistently show that reproducibility is improved considerably by using the advanced algorithm, which also significantly outperforms the basic algorithm. The mean of the mean absolute retinal thickness difference over all data was 9.9 um without motion correction, 7.1 um using the basic algorithm and 5.0 um using the advanced algorithm. Similarly, the blood vessel likelihood map error is reduced to 69% of the uncorrected error for the basic and to 47% of the uncorrected error for the advanced algorithm. These results demonstrate that our advanced motion correction algorithm has the potential to improve the reliability of quantitative measurements derived from 3D-OCT data substantially.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Robust estimation of a location parameter
Huber, P. J. (1964) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177703732 · Cited by 7,228
Cited by
Hwang, T. S., Gao, S. S., Liu, L., Lauer, A. K., Bailey, S. T., Flaxel, C. J., Wilson, D. J., Huang, D., & Jia, Y. (2016) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2015.5658 · Cited by 389
Kuehlewein, L., Bansal, M., Lenis, T. L., Iafe, N. A., Sadda, S. R., Bonini Filho, M. A., De Carlo, T. E., Waheed, N. K., Duker, J. S., & Sarraf, D. (2015) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2015.06.030 · Cited by 344
Self-citationQuantitative OCT Angiography of the Retinal Microvasculature and the Choriocapillaris in Myopic Eyes
Al-Sheikh, M., Phasukkijwatana, N., Dolz-Marco, R., Rahimi, M., Iafe, N. A., Freund, K. B., Sadda, S. R., & Sarraf, D. (2017) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-21289 · Cited by 326
Spaide, R. F. (2015) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2015.04.012 · Cited by 313
Metadata
- Authors
- Kraus, M. F., Liu, J. J., Schottenhamml, J., Chen, C.-L., Budai, A., Branchini, L., Ko, T., Ishikawa, H., Wollstein, G., Schuman, J., Duker, J. S., Fujimoto, J. G., & Hornegger, J.
- Venue
- Biomedical Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2014-07-11
- Volume
- 5
- Issue
- 8
- Pages
- 2591
- ISSN
- 2156-7085 (ISSN-L)
- OpenAlex
- W2014210274
- Cited by
- 169
- References
- 1
- FWCI
- 10.59
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative 3D-OCT motion correction with tilt and illumination correction, robust similarity measure and regularization. https://app.cochat.ai/papers/10.1364/boe.5.002591
- The paper
- Kraus, M. F., Liu, J. J., Schottenhamml, J., Chen, C.-L., Budai, A., Branchini, L., Ko, T., Ishikawa, H., Wollstein, G., Schuman, J., Duker, J. S., Fujimoto, J. G., & Hornegger, J. (2014). Quantitative 3D-OCT motion correction with tilt and illumination correction, robust similarity measure and regularization. Biomedical Optics Express. https://doi.org/10.1364/boe.5.002591
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.