The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Photoelectric Light-Scattering Photometer for Determining High Molecular Weights*
Abstract
A photoelectric photometer designed for the measurement of absolute turbidity, dissymmetry, and depolarization of dilute solutions of high molecular weight materials, and hence determination of their molecular weights, is described. The photometer comprises essentially a monochromatic parallel primary beam of radiation, a six-sided scattering cell for measurements at 0°, 45°, 90°, and 135°, a multiplier phototube and galvanometer, a standard opal glass diffusor, and removable polarizer and analyzer. Turbidity is determined in terms of a ratio of deflections for the 90° scattering and for the primary beam reduced in intensity by neutral filters and diffused by an opal glass plate. Working relationships leading to determination of absolute turbidity are developed. These relationships include corrections for refraction and reflection effects, and for imperfect diffusion by the opal glass. The latter is evaluated by comparison of the opal glass with reflecting diffusors corrected for specular component of reflectance. The response of some multiplier photo-tubes is shown to be dependent on the plane of polarization of the incident radiation. Data illustrating the performance of the photometer include comparison of molecular weights of polystyrene fractions, beta-lactoglobulin, bovine serum albumin, lysozyme, sucrose octaacetate, Raleigh’s ratio and depolarization for benzene, turbidity of a “standard” polystyrene, and particle size of a GR-S latex, with data obtained by other methods or other investigators.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zimm, B. H. (1948) · The Journal of Chemical Physics · doi:10.1063/1.1746740 · Cited by 1,442
Molecular-weight Determination by Light Scattering.
Debye, P. (1947) · The Journal of Physical and Colloid Chemistry · doi:10.1021/j150451a002 · Cited by 1,231
LIGHT-SCATTERING APPARATUS AND TECHNIQUES FOR MEASURING MOLECULAR WEIGHTS OF HIGH POLYMERS
Hadow, H. J., Sheffer, H. E., & Hyde, J. C. (1949) · Canadian Journal of Research · doi:10.1139/cjr49b-081 · Cited by 21
Cited by
Light scattering and the absolute characterization of macromolecules
Wyatt, P. J. (1993) · Analytica Chimica Acta · doi:10.1016/0003-2670(93)80373-s · Cited by 1,436
Viscosity, sedimentation, and light‐scattering properties of fraction of an acid‐hydrolyzed dextran
Senti, F. R., Hellman, N. N., Ludwig, N. H., Babcock, G. E., Tobin, R., Glass, C. A., & Lamberts, B. L. (1955) · Journal of Polymer Science · doi:10.1002/pol.1955.120178605 · Cited by 279
Determination of Mineral Constituents of Rocks by Infrared Spectroscopy
Hunt, J. M., & Turner, D. S. (1953) · Analytical Chemistry · doi:10.1021/ac60080a007 · Cited by 80
Metadata
- Authors
- Brice, B. A., Halwer, M., & Speiser, R.
- Venue
- Journal of the Optical Society of America
- Publisher
- Optica Publishing Group
- Published
- 1950-11-01
- Volume
- 40
- Issue
- 11
- Pages
- 768
- ISSN
- 0030-3941 (ISSN-L)
- OpenAlex
- W2005902516
- Cited by
- 366
- References
- 3
- FWCI
- 23.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Photoelectric Light-Scattering Photometer for Determining High Molecular Weights*. https://app.cochat.ai/papers/10.1364/josa.40.000768
- The paper
- Brice, B. A., Halwer, M., & Speiser, R. (1950). Photoelectric Light-Scattering Photometer for Determining High Molecular Weights*. Journal of the Optical Society of America. https://doi.org/10.1364/josa.40.000768
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.