CoChat

Axicons and Their Uses

McLeod, John H. · 1960 · Journal of the Optical Society of America
Cited by 179

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The most common axicon is a flat cone. A small source of light on the axis of the cone is imaged into a line along a portion of the axis. In lenses the spot diagram has been useful in evaluating image quality. In axicons a corresponding line diagram where lines take the place of dots is useful. In general, axicon instruments correspond to the usual optical instruments. For example, an axicon may be used as an objective to form a telescope. The resulting axicon telescope may be used in aligning machinery such as paper mills. Similarly, an axicon autocollimator may be used to precisely set mirrors perpendicular to a line. One form of axicon microscope has been tried out for the special purpose of locating the position of shiny surfaces without touching them. A most useful form of optical aligner is the reflection cone axicon. It is used as a straight edge. One example is a reflecting cone of 6 in. diam and maximum range of 40 ft with precision of 5 or 6 wavelengths over the entire range. Another example is a 5 in. diam cone with a range of 10 ft and precisions of about 1 wavelength. In this case the use of a suitable radius for the reflecting surface had the effect of making the image brightness substantially uniform over the 10 ft range. Photo cell pickup has been shown to be successful with very high precisions of setting. This opens the way for automatic machine guiding to very high precisions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/josa.50.000166

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 179

Metadata

Authors
McLeod, J. H.
Venue
Journal of the Optical Society of America
Published
1960-02-01
Volume
50
Issue
2
Pages
166
ISSN
0030-3941 (ISSN-L)
OpenAlex
W2040701347
Cited by
179
References
1
FWCI
0.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.