Speckle Removal by a Slowly Moving Diffuser Associated with a Motionless Diffuser
The DOI matches its Crossref record.
Abstract
A moving diffuser destroys the spatial coherence of laser light only partially when the integration time is finite; this can be expressed by the signal-to-noise (S/N) ratio in the observed illuminance, due to the residual speckle. The method can be improved by the use of a two-diffuser system of which one diffuser is motionless, the other moving. In this case, the integration time (or the displacement of the diffuser) required to obtain a given S/N ratio can be greatly reduced, allowing the use of a slowly moving diffuser. Moreover, the S/N ratio does not depend on the optical-system parameters, whereas it depends on these parameters when a single diffuser is used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Images of cone photoreceptors in the living human eye
Miller, D. T., Williams, D. R., Morris, G. M., & Liang, J. (1996) · Vision Research · doi:10.1016/0042-6989(95)00225-1 · Cited by 184
“The beam then passed through two adjacent counter-rotating phase diffusers (Lowenthal & Joyeux, 1971) that scattered the light in a broad range of directions, making the field spatially incoherent.”
BackgroundInfluentialComputational imaging without a computer: seeing through random diffusers at the speed of light
Luo, Y., Zhao, Y., Li, J., Çetintaş, E., Rivenson, Y., Jarrahi, M., & Ozcan, A. (2022) · eLight · doi:10.1186/s43593-022-00012-4 · Cited by 173
“For this choice of diffuser parameters, we further calculated the mean correlation length ( L ) using a phase-autocorrelation function Rd ( x, y ) that is defined as [86] (2) tD ( x, y ) = exp ( j 2π�n D ( x, y ))”
MethodDevos, F., Chavel, P., & Garda, P. (1987) · Optics Letters · doi:10.1364/ol.12.000152 · Cited by 13
Metadata
- Authors
- LOWENTHAL, S., & JOYEUX, D.
- Venue
- Journal of the Optical Society of America
- Publisher
- Optica Publishing Group
- Published
- 1971-07-01
- Volume
- 61
- Issue
- 7
- Pages
- 847
- ISSN
- 0030-3941 (ISSN-L)
- OpenAlex
- W2021708473
- Cited by
- 192
- References
- 0
- FWCI
- 5.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.