Heterochromatic additivity, foveal spectral sensitivity, and a new color model*
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
In three separate experiments it is shown that (i) heterochromatic additivity failures for foveally viewed trichromatic lights can be predicted using a vector model derived from bichromatic additivity data, (ii) near-threshold bichromatic additivity failures are not qualitatively different from threshold-level failures, and (iii) foveal spectral sensitivities obtained by direct brightness matching and threshold methods are greater in the long- and short-wavelength ends of the spectrum than sensitivities obtained by flicker photometry. A new opponent-colors model that is appropriate for threshold-level color vision is expressed as a transformation of the CIE standard observer. The model allows the derivation of a light unit that correlates with signal detectability and predicts (a) confusion lines for deuteranopic and tritanopic vision, (b) spectral sensitivity as measured by flicker photometry (i.e., a sensitivity function much like the CIE Vλ function), (c) spectral sensitivity as measured by threshold (or direct-matching) techniques, (d) threshold-level heterochromatic additivity failures, (e) the apparent saturation of a threshold-level spectrum, (f) wavelength discrimination for a near-threshold spectrum, (g) loci of constant lightness-to-luminance ratios within the CIE chromaticity diagram, and (h) the essential quantitative differences between threshold and near-threshold heterochromatic additivity failures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Coblentz, W. W., & Emerson, W. B. (1918) · Bulletin of the Bureau of Standards · doi:10.6028/bulletin.331 · Cited by 79
Guth, S. L., Alexander, J. V., Chumbly, J. I., Gillman, C. B., & Patterson, M. M. (1968) · Vision Research · doi:10.1016/0042-6989(68)90140-5 · Cited by 70
Self-citation
Cited by
Spectral sensitivity of the foveal cone photopigments between 400 and 500 nm
Smith, V. C., & Pokorny, J. (1975) · Vision Research · doi:10.1016/0042-6989(75)90203-5 · Cited by 1,318
Cardinal directions of color space
Krauskopf, J., Williams, D. R., & Heeley, D. W. (1982) · Vision Research · doi:10.1016/0042-6989(82)90077-3 · Cited by 759
King-Smith, P. E., & Carden, D. (1976) · Journal of the Optical Society of America · doi:10.1364/josa.66.000709 · Cited by 435
Ways of coloring: Comparative color vision as a case study for cognitive science
Thompson, E., Palacios, A., & Varela, F. J. (1992) · Behavioral and Brain Sciences · doi:10.1017/s0140525x00067248 · Cited by 294
Vector model for normal and dichromatic color vision*
Guth, S. L., Massof, R. W., & Benzschawel, T. (1980) · Journal of the Optical Society of America · doi:10.1364/josa.70.000197 · Cited by 235
Self-citation
Metadata
- Authors
- Guth, S. L., & Lodge, H. R.
- Venue
- Journal of the Optical Society of America
- Publisher
- Optica Publishing Group
- Published
- 1973-04-01
- Volume
- 63
- Issue
- 4
- Pages
- 450
- ISSN
- 0030-3941 (ISSN-L)
- OpenAlex
- W2159210839
- Cited by
- 225
- References
- 2
- FWCI
- 3.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.