The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Luminance
Abstract
Luminance was introduced by the CIE as a photometric analog of radiance. This implies that an additive spectral-luminosity function characterizes the human observer. In practice, many different spectral-sensitivity functions characterize human vision, although few produce the additive spectral-luminosity function V (lambda), which is suitable for use in practical photometry. Methods that give rise to additive spectral-sensitivity functions that most resemble V (lambda) tend to have in common the use of spatial or temporal frequencies that will discriminate against signals from the short-wavelength-sensitive cone pathways or against signals in other chromatic pathways. Some of the difference among results obtained with different techniques seems to reflect the extent to which the methods can bring about changes in the state of chromatic adaptation, but it also seems likely that not all tasks tap the same postreceptoral mechanisms. Psychophysical evidence is equivocal regarding the nature of the postreceptoral mechanisms: some evidence suggests just three mechanisms, one of which has a spectral sensitivity that is like V (lambda); other evidence suggests the existence of multiple mechanisms with different spectral sensitivities. Physiological recordings from neurons in the macaque's visual pathway suggest that the properties of the magnocellular system may be sufficient to account for spectral-sensitivity functions measured with the techniques of heterochromatic flicker photometry, minimally distinct border, and critical flicker fusion. These are the psychophysical methods that yield spectral sensitivities that are most like V (lambda). Other methods of measuring spectral sensitivity seem more likely to depend on signals that travel through the parvocellular system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Visual transduction in cones of the monkey Macaca fascicularis.
Schnapf, J. L., Nunn, B. J., Meister, M., & Baylor, D. A. (1990) · The Journal of Physiology · doi:10.1113/jphysiol.1990.sp018193 · Cited by 478
Cited by
The misuse of colour in science communication
Crameri, F., Shephard, G. E., & Heron, P. J. (2020) · Nature Communications · doi:10.1038/s41467-020-19160-7 · Cited by 1,110
Parallel Pathways for Spectral Coding in Primate Retina
Dacey, D. M. (2000) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.23.1.743 · Cited by 440
A model of phototransduction by the human circadian system
Rea, M. S., Figueiro, M. G., Bullough, J. D., & Bierman, A. (2005) · Brain Research Reviews · doi:10.1016/j.brainresrev.2005.07.002 · Cited by 379
Rea, M. S., Figueiro, M. G., Bierman, A., & Bullough, J. D. (2010) · Journal of Circadian Rhythms · doi:10.1186/1740-3391-8-2 · Cited by 279
Gegenfurtner, K. R., & Kiper, D. C. (2003) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.26.041002.131116 · Cited by 272
Metadata
- Authors
- Lennie, P., Pokorny, J., & Smith, V. C.
- Venue
- Journal of the Optical Society of America A
- Publisher
- Optica Publishing Group
- Published
- 1993-06-01
- Volume
- 10
- Issue
- 6
- Pages
- 1283
- ISSN
- 1084-7529 (ISSN-L)
- 1520-8532
- OpenAlex
- W4211067615
- Cited by
- 232
- References
- 1
- FWCI
- 1.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Luminance. https://app.cochat.ai/papers/10.1364/josaa.10.001283
- The paper
- Lennie, P., Pokorny, J., & Smith, V. C. (1993). Luminance. Journal of the Optical Society of America A. https://doi.org/10.1364/josaa.10.001283
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.