The DOI matches its Crossref record.
Analysis of the performance of the Hartmann–Shack sensor in the human eye
Abstract
A description of a Hartmann-Shack sensor to measure the aberrations of the human eye is presented. We performed an analysis of the accuracy and limitations of the sensor using experimental results and computer simulations. We compared the ocular modulation transfer function obtained from simultaneously recorded double-pass and Hartmann-Shack images. The following factors affecting the sensor performance were evaluated: the statistical accuracy, the number of modes used to reconstruct the wave front, the size of the microlenses, and the exposure time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Contribution of the cornea and internal surfaces to the change of ocular aberrations with age
Artal, P., Berrio, E., Guirao, A., & Piers, P. (2002) · Journal of the Optical Society of America A · doi:10.1364/josaa.19.000137 · Cited by 494
Self-citationOptical quality of emmetropic and myopic eyes in the periphery measured with high-angular resolution
Jaeken, B., & Artal, P. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-8993 · Cited by 75
Self-citationWave-aberration control with a liquid crystal on silicon (LCOS) spatial phase modulator
Fernández, E. J., Prieto, P. M., & Artal, P. (2009) · Optics Express · doi:10.1364/oe.17.011013 · Cited by 57
Self-citationComparison of aberrations in different types of progressive power lenses
Villegas, E. A., & Artal, P. (2004) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2004.00214.x · Cited by 32
Self-citation
Metadata
- Authors
- Prieto, P. M., Vargas-Martı́n, F., Goelz, S., & Artal, P.
- Venue
- Journal of the Optical Society of America A
- Publisher
- Optica Publishing Group
- Published
- 2000-08-01
- Volume
- 17
- Issue
- 8
- Pages
- 1388
- ISSN
- 1084-7529 (ISSN-L)
- 1520-8532
- OpenAlex
- W2053841729
- Cited by
- 298
- References
- 0
- FWCI
- 8.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analysis of the performance of the Hartmann–Shack sensor in the human eye. https://app.cochat.ai/papers/10.1364/josaa.17.001388
- The paper
- Prieto, P. M., Vargas-Martı́n, F., Goelz, S., & Artal, P. (2000). Analysis of the performance of the Hartmann–Shack sensor in the human eye. Journal of the Optical Society of America A. https://doi.org/10.1364/josaa.17.001388
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.