The DOI matches its Crossref record.
Automated identification of cone photoreceptors in adaptive optics retinal images
Abstract
In making noninvasive measurements of the human cone mosaic, the task of labeling each individual cone is unavoidable. Manual labeling is a time-consuming process, setting the motivation for the development of an automated method. An automated algorithm for labeling cones in adaptive optics (AO) retinal images is implemented and tested on real data. The optical fiber properties of cones aided the design of the algorithm. Out of 2153 manually labeled cones from six different images, the automated method correctly identified 94.1% of them. The agreement between the automated and the manual labeling methods varied from 92.7% to 96.2% across the six images. Results between the two methods disagreed for 1.2% to 9.1% of the cones. Voronoi analysis of large montages of AO retinal images confirmed the general hexagonal-packing structure of retinal cones as well as the general cone density variability across portions of the retina. The consistency of our measurements demonstrates the reliability and practicality of having an automated solution to this problem.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dry Age-Related Macular Degeneration: Mechanisms, Therapeutic Targets, and Imaging
Bowes Rickman, C., Farsiu, S., Toth, C. A., & Klingeborn, M. (2013) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.13-12757 · Cited by 282
Talcott, K. E., Ratnam, K., Sundquist, S. M., Lucero, A. S., Lujan, B. J., Tao, W., Porco, T. C., Roorda, A., & Duncan, J. L. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6479 · Cited by 276
Self-citationAdaptive optics imaging of the human retina
Burns, S. A., Elsner, A. E., Sapoznik, K. A., Warner, R. L., & Gast, T. J. (2019) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.08.002 · Cited by 263
Cone photoreceptor mosaic disruption associated with Cys203Arg mutation in the M-cone opsin
Carroll, J., Baraas, R. C., Wagner-Schuman, M., Rha, J., Siebe, C. A., Sloan, C., Tait, D. M., Thompson, S., Morgan, J. I. W., Neitz, J., et al. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0910128106 · Cited by 59
Carroll, J., Rossi, E. A., Porter, J., Neitz, J., Roorda, A., Williams, D. R., & Neitz, M. (2010) · Vision Research · doi:10.1016/j.visres.2010.07.009 · Cited by 49
Self-citation
Metadata
- Authors
- Li, K. Y., & Roorda, A.
- Venue
- Journal of the Optical Society of America A
- Publisher
- Optica Publishing Group
- Published
- 2007-04-11
- Volume
- 24
- Issue
- 5
- Pages
- 1358
- ISSN
- 1084-7529 (ISSN-L)
- 1520-8532
- OpenAlex
- W2137099832
- Cited by
- 222
- References
- 0
- FWCI
- 5.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated identification of cone photoreceptors in adaptive optics retinal images. https://app.cochat.ai/papers/10.1364/josaa.24.001358
- The paper
- Li, K. Y., & Roorda, A. (2007). Automated identification of cone photoreceptors in adaptive optics retinal images. Journal of the Optical Society of America A. https://doi.org/10.1364/josaa.24.001358
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.