The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Experimental comparison of single-pixel imaging algorithms
Open accessAbstract
Single-pixel imaging (SPI) is a novel technique that captures 2D images using a photodiode, instead of conventional 2D array sensors. SPI has high signal-to-noise ratio, wide spectral range, low cost, and robustness to light scattering. Various algorithms have been proposed for SPI reconstruction, including linear correlation methods, the alternating projection (AP) method, and compressive sensing (CS) based methods. However, there has been no comprehensive review discussing respective advantages, which is important for SPI's further applications and development. In this paper, we review and compare these algorithms in a unified reconstruction framework. We also propose two other SPI algorithms, including a conjugate gradient descent (CGD) based method and a Poisson maximum-likelihood-based method. Both simulations and experiments validate the following conclusions: to obtain comparable reconstruction accuracy, the CS-based total variation (TV) regularization method requires the fewest measurements and consumes the least running time for small-scale reconstruction, the CGD and AP methods run fastest in large-scale cases, and the TV and AP methods are the most robust to measurement noise. In a word, there are trade-offs in capture efficiency, computational complexity, and robustness to noise among different SPI algorithms. We have released our source code for non-commercial use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction To Compressive Sampling
Candes, E. J., & Wakin, M. B. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914731 · Cited by 10,017
Cited by
Far-field super-resolution ghost imaging with a deep neural network constraint
Wang, F., Wang, C., Chen, M., Gong, W., Zhang, Y., Han, S., & Situ, G. (2022) · Light: Science & Applications · doi:10.1038/s41377-021-00680-w · Cited by 400
Metasurface-based key for computational imaging encryption
Zheng, P., Dai, Q., Li, Z., Ye, Z., Xiong, J., Liu, H.-C., Zheng, G., & Zhang, S. (2021) · Science Advances · doi:10.1126/sciadv.abg0363 · Cited by 347
Self-citation
Metadata
- Authors
- Bian, L., Suo, J., Dai, Q., & Chen, F.
- Venue
- Journal of the Optical Society of America A
- Publisher
- Optica Publishing Group
- Published
- 2017-12-12
- Volume
- 35
- Issue
- 1
- Pages
- 78
- ISSN
- 1084-7529 (ISSN-L)
- 1520-8532
- OpenAlex
- W2734545110
- Cited by
- 220
- References
- 1
- FWCI
- 4.45
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Experimental comparison of single-pixel imaging algorithms. https://app.cochat.ai/papers/10.1364/josaa.35.000078
- The paper
- Bian, L., Suo, J., Dai, Q., & Chen, F. (2018). Experimental comparison of single-pixel imaging algorithms. Journal of the Optical Society of America A. https://doi.org/10.1364/josaa.35.000078
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.