The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Temporal modulation sensitivity and pulse-detection thresholds for chromatic and luminance perturbations
Abstract
We studied temporal processing of chromatic and luminance perturbations of a 600-nm field, measuring both modulation sensitivity (sinusoidal frequencies from 0.25 to 40 Hz) and pulse-detection thresholds (pulse durations from 5 to 2560 msec) for mean luminances of 0.9 to 900 Td and field sizes of 0.5 degrees to 8 degrees. Chromatic stimuli were produced by antiphase modulation of lights matched by heterochromatic flicker photometry. Both mean luminance and field size affected sensitivity, and the magnitude of field-size effects increased with mean luminance. We derived both luminance and chromatic impulse response functions for each set of experimental conditions, using the modulation-sensitivity data. At high mean luminances and large field sizes the chromatic impulse response functions are complex, suggesting contributions from both chromatic and luminance mechanisms. Pulse-detection data were fitted by a peak detector model based on these impulse response functions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
de Lange Dzn, H. (1958) · Journal of the Optical Society of America · doi:10.1364/josa.48.000777 · Cited by 596
Visual Responses to Time-Dependent Stimuli* I Amplitude Sensitivity Measurements†
Kelly, D. H. (1961) · Journal of the Optical Society of America · doi:10.1364/josa.51.000422 · Cited by 575
Spatiotemporal variation of chromatic and achromatic contrast thresholds
Kelly, D. H. (1983) · Journal of the Optical Society of America · doi:10.1364/josa.73.000742 · Cited by 260
Reconstruction of the electrical responses of turtle cones to flashes and steps of light
Baylor, D. A., Hodgkin, A. L., & Lamb, T. D. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010733 · Cited by 234
Two-band model of heterochromatic flicker
Kelly, D. H., & van Norren, D. (1977) · Journal of the Optical Society of America · doi:10.1364/josa.67.001081 · Cited by 190
Patterns of temporal interaction in the detection of gratings
Watson, A. B., & Nachmias, J. (1977) · Vision Research · doi:10.1016/0042-6989(77)90063-3 · Cited by 185
New look at Bloch’s law for contrast
Goréa, A., & Tyler, C. W. (1986) · Journal of the Optical Society of America A · doi:10.1364/josaa.3.000052 · Cited by 140
Tyler, C. W. (1985) · Journal of the Optical Society of America A · doi:10.1364/josaa.2.000393 · Cited by 137
Second-site adaptation in the red-green chromatic pathways
Stromeyer, C. F., Cole, G. R., & Kronauer, R. E. (1985) · Vision Research · doi:10.1016/0042-6989(85)90116-6 · Cited by 136
Dynamic properties of vision—IV
Roufs, J. A. J. (1974) · Vision Research · doi:10.1016/0042-6989(74)90148-5 · Cited by 117
Chromatic suppression of cone inputs to the luminance flicker mechanism
Stromeyer, C. F., Cole, G. R., & Kronauer, R. E. (1987) · Vision Research · doi:10.1016/0042-6989(87)90026-5 · Cited by 90
Threshold temporal integration of chromatic stimuli
Smith, V. C., Bowen, R. W., & Pokorny, J. (1984) · Vision Research · doi:10.1016/0042-6989(84)90206-2 · Cited by 84
Self-citationWisowaty, J. J., & Boynton, R. M. (1980) · Vision Research · doi:10.1016/0042-6989(80)90071-1 · Cited by 83
Daly, S. J., & Normann, R. A. (1985) · Vision Research · doi:10.1016/0042-6989(85)90034-3 · Cited by 59
Calibration of the retinal illuminance provided by maxwellian views
Nygaard, R. W., & Frumkes, T. E. (1982) · Vision Research · doi:10.1016/0042-6989(82)90189-4 · Cited by 50
Ikeda, M. (1986) · Vision Research · doi:10.1016/0042-6989(86)90166-5 · Cited by 49
Theory of flicker and transient responses III An essential nonlinearity
Kelly, D. H., & Savoie, R. E. (1978) · Journal of the Optical Society of America · doi:10.1364/josa.68.001481 · Cited by 48
Prediction of flicker sensitivities from temporal three-pulse data
Bergen, J. R., & Wilson, H. R. (1985) · Vision Research · doi:10.1016/0042-6989(85)90163-4 · Cited by 45
Cited by
Dacey, D. M., & Lee, B. B. (1994) · Nature · doi:10.1038/367731a0 · Cited by 582
Luminance and chromatic modulation sensitivity of macaque ganglion cells and human observers
Lee, B. B., Pokorny, J., Martin, P. R., Valbergt, A., & Smith, V. C. (1990) · Journal of the Optical Society of America A · doi:10.1364/josaa.7.002223 · Cited by 504
Self-citationExtraretinal Control of Saccadic Suppression
Diamond, M. R., Ross, J., & Morrone, M. C. (2000) · The Journal of Neuroscience · doi:10.1523/jneurosci.20-09-03449.2000 · Cited by 311
Sensitivity of macaque retinal ganglion cells to chromatic and luminance flicker.
Lee, B. B., Martin, P. R., & Valberg, A. (1989) · The Journal of Physiology · doi:10.1113/jphysiol.1989.sp017685 · Cited by 310
Chapter 7 New views of primate retinal function
Kaplan, E., Lee, B. B., & Shapley, R. M. (1990) · Progress in Retinal Research · doi:10.1016/0278-4327(90)90009-7 · Cited by 282
Metadata
- Authors
- Swanson, W. H., Ueno, T., Smith, V. C., & Pokorny, J.
- Venue
- Journal of the Optical Society of America A
- Publisher
- Optica Publishing Group
- Published
- 1987-10-01
- Volume
- 4
- Issue
- 10
- Pages
- 1992
- ISSN
- 1084-7529 (ISSN-L)
- 1520-8532
- OpenAlex
- W2164833011
- Cited by
- 268
- References
- 18
- FWCI
- 3.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.