The DOI matches its Crossref record.
Membrane imaging by second-harmonic generation microscopy
Open accessAbstract
We present a detailed analysis of the generation of second-harmonic radiation from biological membranes labeled with a styryl dye. In particular, we consider the high-numerical-aperture limit appropriate to high-resolution microscopy in which an excitation beam is tightly focused from the side onto a membrane surface. In this limit the active surface area that contributes to second-harmonic generation (SHG) depends only on the tightness of the beam focus and the SHG radiation is confined by phase matching into two well-defined off-axis lobes. We derive expressions for the SHG radiation power, angular distribution, and polarization dependence in the cases of ideal or nonideal molecular alignment in the membrane and uniaxiality of the molecular hyperpolarizability. We define an SHG cross section similar to that used in two-photon-excited fluorescence (TPEF) to permit direct comparison of the two imaging modalities. Finally, we corroborate our results with experiments based on the excitation of a styryl dye in giant unilamellar vesicles with a mode-locked Ti:sapphire laser.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Campagnola, P. J., & Loew, L. M. (2003) · Nature Biotechnology · doi:10.1038/nbt894 · Cited by 1,326
Coherent Anti-Stokes Raman Scattering Microscopy: Instrumentation, Theory, and Applications
Cheng, J.-X., & Xie, X. S. (2004) · The Journal of Physical Chemistry B · doi:10.1021/jp035693v · Cited by 963
Dynamic imaging of collagen and its modulation in tumors in vivo using second-harmonic generation
Brown, E., McKee, T., diTomaso, E., Pluen, A., Seed, B., Boucher, Y., & Jain, R. K. (2003) · Nature Medicine · doi:10.1038/nm879 · Cited by 836
Imaging through glass diffusers using densely connected convolutional networks
Li, S., Deng, M., Lee, J., Sinha, A., & Barbastathis, G. (2018) · Optica · doi:10.1364/optica.5.000803 · Cited by 435
Laser-Scanning Coherent Anti-Stokes Raman Scattering Microscopy and Applications to Cell Biology
Cheng, J.-X., Jia, Y. K., Zheng, G., & Xie, X. S. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75186-2 · Cited by 371
Metadata
- Authors
- Moreaux, L., Sandre, O., & Mertz, J.
- Venue
- Journal of the Optical Society of America B
- Publisher
- Optica Publishing Group
- Published
- 2000-10-01
- Volume
- 17
- Issue
- 10
- Pages
- 1685
- ISSN
- 0740-3224 (ISSN-L)
- 1520-8540
- OpenAlex
- W1979096832
- Cited by
- 345
- References
- 0
- FWCI
- 9.19
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Membrane imaging by second-harmonic generation microscopy. https://app.cochat.ai/papers/10.1364/josab.17.001685
- The paper
- Moreaux, L., Sandre, O., & Mertz, J. (2000). Membrane imaging by second-harmonic generation microscopy. Journal of the Optical Society of America B. https://doi.org/10.1364/josab.17.001685
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.