The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Adaptive optics with a magnetic deformable mirror: applications in the human eye
Open accessAbstract
A novel deformable mirror using 52 independent magnetic actuators (MIRAO 52, Imagine Eyes) is presented and characterized for ophthalmic applications. The capabilities of the device to reproduce different surfaces, in particular Zernike polynomials up to the fifth order, are investigated in detail. The study of the influence functions of the deformable mirror reveals a significant linear response with the applied voltage. The correcting device also presents a high fidelity in the generation of surfaces. The ranges of production of Zernike polynomials fully cover those typically found in the human eye, even for the cases of highly aberrated eyes. Data from keratoconic eyes are confronted with the obtained ranges, showing that the deformable mirror is able to compensate for these strong aberrations. Ocular aberration correction with polychromatic light, using a near Gaussian spectrum of 130 nm full width at half maximum centered at 800 nm, in five subjects is accomplished by simultaneously using the deformable mirror and an achromatizing lens, in order to compensate for the monochromatic and chromatic aberrations, respectively. Results from living eyes, including one exhibiting 4.66 D of myopia and a near pathologic cornea with notable high order aberrations, show a practically perfect aberration correction. Benefits and applications of simultaneous monochromatic and chromatic aberration correction are finally discussed in the context of retinal imaging and vision.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ultrahigh-resolution ophthalmic optical coherence tomography
Drexler, W., Morgner, U., Ghanta, R. K., Kärtner, F. X., Schuman, J. S., & Fujimoto, J. G. (2001) · Nature Medicine · doi:10.1038/86589 · Cited by 962
Self-citation
Cited by
State-of-the-art retinal optical coherence tomography
DREXLER, W., & FUJIMOTO, J. (2008) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2007.07.005 · Cited by 906
Self-citationAdaptive optics via pupil segmentation for high-resolution imaging in biological tissues
Ji, N., Milkie, D. E., & Betzig, E. (2010) · Nature Methods · doi:10.1038/nmeth.1411 · Cited by 585
Adaptive optics imaging of the human retina
Burns, S. A., Elsner, A. E., Sapoznik, K. A., Warner, R. L., & Gast, T. J. (2019) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.08.002 · Cited by 263
Benard, Y., Lopez-Gil, N., & Legras, R. (2011) · Vision Research · doi:10.1016/j.visres.2011.10.003 · Cited by 101
Wave-aberration control with a liquid crystal on silicon (LCOS) spatial phase modulator
Fernández, E. J., Prieto, P. M., & Artal, P. (2009) · Optics Express · doi:10.1364/oe.17.011013 · Cited by 57
Metadata
- Authors
- Fernandez, E. J., Vabre, L., Hermann, B., Unterhuber, A., Povazay, B., & Drexler, W.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2006
- Volume
- 14
- Issue
- 20
- Pages
- 8900
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2028475655
- Cited by
- 158
- References
- 1
- FWCI
- 8.81
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Adaptive optics with a magnetic deformable mirror: applications in the human eye. https://app.cochat.ai/papers/10.1364/oe.14.008900
- The paper
- Fernandez, E. J., Vabre, L., Hermann, B., Unterhuber, A., Povazay, B., & Drexler, W. (2006). Adaptive optics with a magnetic deformable mirror: applications in the human eye. Optics Express. https://doi.org/10.1364/oe.14.008900
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.