The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Robust flow measurement with multi-exposure speckle imaging
Open accessAbstract
Laser Speckle Contrast Imaging (LSCI) is a minimally invasive full field optical technique used to generate blood flow maps with high spatial and temporal resolution. The lack of quantitative accuracy and the inability to predict flows in the presence of static scatterers such as an intact or thinned skull have been the primary limitation of LSCI. We present a new Multi-Exposure Speckle Imaging (MESI) instrument that has potential to obtain quantitative baseline flow measures. We show that the MESI instrument extends the range over which relative flow measurements are linear. We also present a new speckle model which can discriminate flows in the presence of static scatters. We show that in the presence of static scatterers the new model used along with the new MESI instrument can predict correlation times of flow consistently to within 10% of the value without static scatterers compared to an average deviation of more than 100% from the value without static scatterers using traditional LSCI. We also show that the new speckle model used with the MESI instrument can maintain the linearity of relative flow measurements in the presence of static scatterers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic Light Scattering: With Applications to Chemistry, Biology, and Physics
Berne, B. J., & Pecora, R. (1976) · CERN Document Server (European Organization for Nuclear Research) · Cited by 2,856
In vivo evaluation of microcirculation by coherent light scattering
STERN, M. D. (1975) · Nature · doi:10.1038/254056a0 · Cited by 857
Model for laser Doppler measurements of blood flow in tissue
Bonner, R., & Nossal, R. (1981) · Applied Optics · doi:10.1364/ao.20.002097 · Cited by 836
Dynamic Imaging of Cerebral Blood Flow Using Laser Speckle
Dunn, A. K., Bolay, H., Moskowitz, M. A., & Boas, D. A. (2001) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200103000-00002 · Cited by 826
Self-citationAnderson, J. R., Chiu, D. T., Jackman, R. J., Cherniavskaya, O., McDonald, J. C., Wu, H., Whitesides, S. H., & Whitesides, G. M. (2000) · Analytical Chemistry · doi:10.1021/ac9912294 · Cited by 698
Flow visualization by means of single-exposure speckle photography
Fercher, A. F., & Briers, J. D. (1981) · Optics Communications · doi:10.1016/0030-4018(81)90428-4 · Cited by 670
Boas, D. A., & Yodh, A. G. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.000192 · Cited by 606
Dunn, A. K., Devor, A., Dale, A. M., & Boas, D. A. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.04.024 · Cited by 285
Self-citationAyata, C., Dunn, A. K., Gursoy-Özdemir, Y., Huang, Z., Boas, D. A., & Moskowitz, M. A. (2004) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/01.wcb.0000122745.72175.d5 · Cited by 276
Self-citationModified laser speckle imaging method with improved spatial resolution
Cheng, H., Luo, Q., Zeng, S., Chen, S., Cen, J., & Gong, H. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1578089 · Cited by 256
Cited by
Laser speckle contrast imaging in biomedical optics
Boas, D. A., & Dunn, A. K. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3285504 · Cited by 1,122
Self-citationReview of laser speckle contrast techniques for visualizing tissue perfusion
Draijer, M., Hondebrink, E., van Leeuwen, T., & Steenbergen, W. (2009) · Lasers in Medical Science · doi:10.1007/s10103-008-0626-3 · Cited by 380
Vascular remodeling after ischemic stroke: mechanisms and therapeutic potentials.
Liu, J., Wang, Y., Akamatsu, Y., Lee, C. C., Stetler, R. A., Lawton, M. T., & Yang, G.-Y. (2014) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2013.11.004 · Cited by 335
Laser Speckle Contrast Imaging of Cerebral Blood Flow
Dunn, A. K. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0469-0 · Cited by 278
Self-citationLaser Speckle Contrast Imaging: Theory, Instrumentation and Applications
Senarathna, J., Rege, A., Li, N., & Thakor, N. V. (2013) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2013.2243140 · Cited by 269
Metadata
- Authors
- Parthasarathy, A. B., Tom, W. J., Gopal, A., Zhang, X., & Dunn, A. K.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2008
- Volume
- 16
- Issue
- 3
- Pages
- 1975
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2034762861
- Cited by
- 367
- References
- 19
- FWCI
- 10.51
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Robust flow measurement with multi-exposure speckle imaging. https://app.cochat.ai/papers/10.1364/oe.16.001975
- The paper
- Parthasarathy, A. B., Tom, W. J., Gopal, A., Zhang, X., & Dunn, A. K. (2008). Robust flow measurement with multi-exposure speckle imaging. Optics Express. https://doi.org/10.1364/oe.16.001975
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.