The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
STED microscopy with a supercontinuum laser source
Open accessAbstract
We report on a straightforward yet powerful implementation of stimulated emission depletion (STED) fluorescence microscopy providing subdiffraction resolution in the far-field. Utilizing the same super-continuum pulsed laser source both for excitation and STED, this implementation of STED microscopy avoids elaborate preparations of laser pulses and conveniently provides multicolor imaging. Operating at pulse repetition rates around 1 MHz, it also affords reduced photobleaching rates by allowing the fluorophore to relax from excitable metastable dark states involved in photodegradation. The imaging of dense nanoparticles and of the microtubular network of mammalian cells evidences a spatial resolution of 30-50 nm in the focal plane, i.e. by a factor of 8-9 beyond the diffraction barrier.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967
Self-citation
Cited by
Stimulated Emission Depletion Microscopy
Blom, H., & Widengren, J. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00653 · Cited by 339
Two-photon excitation STED microscopy
Moneron, G., & Hell, S. W. (2009) · Optics Express · doi:10.1364/oe.17.014567 · Cited by 238
Self-citation
Metadata
- Authors
- Wildanger, D., Rittweger, E., Kastrup, L., & Hell, S. W.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2008-06-13
- Volume
- 16
- Issue
- 13
- Pages
- 9614
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2078085621
- Cited by
- 277
- References
- 1
- FWCI
- 9.69
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: STED microscopy with a supercontinuum laser source. https://app.cochat.ai/papers/10.1364/oe.16.009614
- The paper
- Wildanger, D., Rittweger, E., Kastrup, L., & Hell, S. W. (2008). STED microscopy with a supercontinuum laser source. Optics Express. https://doi.org/10.1364/oe.16.009614
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.