The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Deep tissue multiphoton microscopy using longer wavelength excitation
Open accessAbstract
We compare the maximal two-photon fluorescence microscopy (TPM) imaging depth achieved with 775-nm excitation to that achieved with 1280-nm excitation through in vivo and ex vivo TPM of fluorescently-labeled blood vessels in mouse brain. We achieved high contrast imaging of blood vessels at approximately twice the depth with 1280-nm excitation as with 775-nm excitation. An imaging depth of 1 mm can be achieved in in vivo imaging of adult mouse brains at 1280 nm with approximately 1-nJ pulse energy at the sample surface. Blood flow speed measurements at a depth of 900 mum are performed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Kleinfeld, D., Mitra, P. P., Helmchen, F., & Denk, W. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.26.15741 · Cited by 832
Schaffer, C. B., Friedman, B., Nishimura, N., Schroeder, L. F., Tsai, P. S., Ebner, F. F., Lyden, P. D., & Kleinfeld, D. (2006) · PLoS Biology · doi:10.1371/journal.pbio.0040022 · Cited by 400
Self-citationShih, A. Y., Friedman, B., Drew, P. K., Tsai, P. S., Lyden, P. D., & Kleinfeld, D. (2009) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2008.166 · Cited by 127
Cited by
Ultrasensitive fluorescent proteins for imaging neuronal activity
Chen, T.-W., Wardill, T. J., Sun, Y., Pulver, S. R., Renninger, S. L., Baohan, A., Schreiter, E. R., Kerr, R. A., Orger, M. B., Jayaraman, V., et al. (2013) · Nature · doi:10.1038/nature12354 · Cited by 6,474
In vivo three-photon microscopy of subcortical structures within an intact mouse brain
Horton, N. G., Wang, K., Kobat, D., Clark, C. G., Wise, F. W., Schaffer, C. B., & Xu, C. (2013) · Nature Photonics · doi:10.1038/nphoton.2012.336 · Cited by 1,505
Self-citationGrienberger, C., & Konnerth, A. (2012) · Neuron · doi:10.1016/j.neuron.2012.02.011 · Cited by 1,354
Liu, Q., Guo, B., Rao, Z., Zhang, B., & Gong, J. R. (2013) · Nano Letters · doi:10.1021/nl400368v · Cited by 958
Bouchard, M. B., Voleti, V., Mendes, C. S., Lacefield, C., Grueber, W. B., Mann, R. S., Bruno, R. M., & Hillman, E. M. C. (2015) · Nature Photonics · doi:10.1038/nphoton.2014.323 · Cited by 566
Metadata
- Authors
- Kobat, D., Durst, M. E., Nishimura, N., Wong, A. W., Schaffer, C. B., & Xu, C.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2009-07-20
- Volume
- 17
- Issue
- 16
- Pages
- 13354
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2023639738
- Cited by
- 574
- References
- 4
- FWCI
- 16.69
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Deep tissue multiphoton microscopy using longer wavelength excitation. https://app.cochat.ai/papers/10.1364/oe.17.013354
- The paper
- Kobat, D., Durst, M. E., Nishimura, N., Wong, A. W., Schaffer, C. B., & Xu, C. (2009). Deep tissue multiphoton microscopy using longer wavelength excitation. Optics Express. https://doi.org/10.1364/oe.17.013354
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.