Cited by 95Terahertz technology and applicationsSpectroscopy and Laser ApplicationsLaser-Matter Interactions and Applications

Rapid-scanning terahertz precision spectrometer with more than 6 THz spectral coverage

Open access
Klatt, G., Gebs, R., Janke, C., Dekorsy, T., Bartels, A.·2009·Optics Express

Abstract

We report a terahertz time-domain spectrometer with more than 6 THz spectral coverage and 1 GHz resolution based on high-speed asynchronous optical sampling. It operates at 2 kHz scan rate without mechanical delay stage. The frequency error of the system at 60 s acquisition time is determined by comparing a measured water vapor absorption spectrum to data reported in the HITRAN database. The mean error of 87 evaluated absorption lines is 142 MHz.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/oe.17.022847

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Most ASOPS THz-TDS techniques use IFG, sum-frequency generation, or two-photon absorption of pulsed lasers as a trigger for signal accumulation.

    “Most ASOPS THz-TDS techniques use IFG, sum-frequency generation, or twophoton absorption of pulsed lasers as a trigger for signal accumulation [3,11,12,18,31].”

    From Jitter correction for asynchronous optical sampling terahertz spectroscopy using free-running pulsed lasers (2023) · cites this paper as [11]

    The Experimental setup (p. 3) says this ASOPS THz-TDS instrument generates its data-acquisition trigger optically through two-photon absorption. It does not establish that most ASOPS THz-TDS techniques use the listed triggers, or describe IFG or sum-frequency generation as trigger methods. (LLM, conf=0.86)

    Experimental — accuracy not yet measured
  • The concept of our method is similar to that of previous studies on frequency stabilization by locking ∆f_r or its harmonics.

    “In this context, the concept of our method is similar to that of previous studies on frequency stabilization by locking ∆𝑓 r or its harmonics [2,11].”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 21

  1. [1]1. M. Tonouchi, "Cutting-edge terahertz technology," Nat. Photonics 1(2), 97–105 (2007).
  2. [3]3. H. Harde, R. A. Cheville, and D. Grischkowsky, "Terahertz studies of collision-broadened rotational lines," J. Phys. Chem. A 101(20), 3646–3660 (1997).
  3. [2]2. D. Mittleman, Sensing with terahertz radiation, Springer series in optical sciences (Springer, 2003).
  4. [4]4. C. Fattinger, and D. Grischkowsky, "Terahertz beams," Appl. Phys. Lett. 54(6), 490–492 (1989).
  5. [6]6. R. Huber, A. Brodschelm, F. Tauser, and A. Leitenstorfer, "Generation and field-resolved detection of femtosecond electromagnetic pulses tunable up to 41 THz," Appl. Phys. Lett. 76(22), 3191–3193 (2000).
  6. [5]5. X.-C. Zhang, B. B. Hu, J. T. Darrow, and D. H. Auston, "Generation of femtosecond electromagnetic pulses from semiconductòr surfaces," Appl. Phys. Lett. 56(11), 1011–1013 (1990).
  7. [9]9. S. Kim, B. Born, M. Havenith, and M. Gruebele, "Échtzeitnachweis von Änderungen im ProteinWassernetzwerk während der Proteinfaltung mit Terahertz-Absorptionsspektroskopie," Angew. Chem. 120(34), 6586–6589 (2008).
  8. [9]9. kd- s -t , e e e ed asynchronous optical sampling," Electron. Lett. 45(6), 310–311 (2009).
  9. [12]12. G.-J. Kim, S.-G. Jeon, J.-I. Kim, and Y.-S. Jin, "Terahertz Pulse Detection Using Rotary Optical Delay Line," Jpn. J. Appl. Phys. 46(11), 7332–7335 (2007).
  10. [11]11. J. Xu, and X.-C. Zhang, "Circular involute stage," Opt. Lett. 29(17), 2082–2084 (2004).
  11. [13]13. P. A. Elzinga, R. J. Kneisler, F. E. Lytle, Y. Jiang, G. B. King, and N. M. Laurendeau, "Pump/probe method for fast analysis of visible spectral signatures utilizing asynchronous optical sampling," Appl. Opt. 26(19), 4303– 4309 (1987).
  12. [17]17. S. S. Harsha, N. Laman, and D. Grischkowsky, "High-Q terahertz Bragg resonances within a metal parallel plate waveguide," Appl. Phys. Lett. 94(9), 091118 (2009). Konstanzer Online-Publikations-System (KOPS) URN: http://nbn-resolving.de/urn:nbn:de:bsz:352-opus-98711 URL: http://kops.ub.uni-konstanz.de/volltexte/2009/9871/
  13. [18]18. R. Gebs, G. Klatt, H. Schafer, T. Dekorsy, and A. Bartels, Sub-100 fs time-domain spectroscopy using highspeed ASOPS, in Lasers and Electro-Optics 2009 and the European Quantum Electronics Conference. CLEO Europe - EQEC 2009 (2009).
  14. [20]20. J. K. Wahlstrand, and R. Merlin, "Cherenkov radiation emitted by ultrafast laser pulses and the generation of coherent polaritons," Phys. Rev. B 68(5), 054301 (2003).
  15. [19]19. A. Leitenstorfer, S. Hunsche, J. Shah, M. C. Nuss, and W. H. Knox, "Detectors and sources for ultrabroadband electro-optic sampling: Experiment and theory," Appl. Phys. Lett. 74(11), 1516–1518 (1999).
  16. [21]21. R. Chakkittakandy, J. A. Corver, and P. C. Planken, "Quasi-near field terahertz generation and detection," Opt. Express 16(17), 12794–12805 (2008).
  17. [23]23. D. L. Mills, and E. Burstein, "Polaritons: the electromagnetic modes of media," Rep. Prog. Phys. 37(7), 817–926 (1974).
  18. [22]22. A. Dreyhaupt, S. Winnerl, T. Dekorsy, and M. Helm, "High-intensity terahertz radiation from a microstructured large-area photoconductor," Appl. Phys. Lett. 86(12), 121114–3 (2005).
  19. [24]24. W. L. Faust, and C. H. Henry, "Mixing of Visible and Near-Resonance Infrared Light in GaP," Phys. Rev. Lett. 17(25), 1265–1268 (1966).
  20. [26]26. M. Exter, C. Fattinger, and D. Grischkowsky, "Terahertz time-domain spectroscopy of water vapor," Opt. Lett. 14(20), 1128–1130 (1989).
  21. [25]25. S. Kasai, T. Katagiri, J. Takayanagi, K. Kawase, and T. Ouchi, "Reduction of phonon resonant terahertz wave absorption in photoconductive switches using epitaxial layer transfer," Appl. Phys. Lett. 94(11), 113505 (2009).

Cited by

Sorted by citations

Authors
Klatt, G., Gebs, R., Janke, C., Dekorsy, T., & Bartels, A.
Affiliations
University of Konstanz (DE)
Venue
Optics Express
Published
2009-11-30
Volume
17
Issue
25
Pages
22847
ISSN
1094-4087 (ISSN-L)
OpenAlex
W2170671789
Cited by
95
References
2
Citations by year
2026: 4 · 2025: 3 · 2024: 4 · 2023: 4 · 2022: 4 · 2021: 3 · 2020: 1 · 2019: 5 · 2018: 12 · 2017: 6 · 2016: 6 · 2015: 7 · 2014: 5 · 2013: 3 · 2012: 7
FWCI
7.40
Type
journal article
Language
en
Open access
Locations
  • Optics Express (publishedVersion)
  • PubMed (publishedVersion)
  • KOPS (University of Konstanz) (submittedVersion)
Funders
Deutsche Forschungsgemeinschaft
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
  • Physical Sciences › Chemistry › Spectroscopy › Spectroscopy and Laser Applications
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
Keywords
terahertz time-domain spectroscopy, asynchronous optical sampling, high-speed sampling, HITRAN comparison, spectral resolution
MeSH terms
Equipment Design, Computer-Aided Design, Equipment Failure Analysis, Terahertz Radiation, Terahertz Spectroscopy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review