CoChat

Optical sampling by laser cavity tuning

Open access
Hochrein, Thomas, Wilk, Rafal, Mei, Michael, Holzwarth, Ronald, Krumbholz, Norman, Koch, Martin · 2010 · Optics Express
Cited by 129

The DOI matches its Crossref record.

Abstract

Most time-resolved optical experiments rely either on external mechanical delay lines or on two synchronized femtosecond lasers to achieve a defined temporal delay between two optical pulses. Here, we present a new method which does not require any external delay lines and uses only a single femtosecond laser. It is based on the cross-correlation of an optical pulse with a subsequent pulse from the same laser. Temporal delay between these two pulses is achieved by varying the repetition rate of the laser. We validate the new scheme by a comparison with a cross-correlation measurement carried out with a conventional mechanical delay line.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/oe.18.001613

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 129

Metadata

Authors
Hochrein, T., Wilk, R., Mei, M., Holzwarth, R., Krumbholz, N., & Koch, M.
Venue
Optics Express
Published
2010-01-13
Volume
18
Issue
2
Pages
1613
ISSN
1094-4087 (ISSN-L)
OpenAlex
W2058407178
Cited by
129
References
0
FWCI
4.83
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Optical sampling by laser cavity tuning. https://app.cochat.ai/papers/10.1364/oe.18.001613
The paper
Hochrein, T., Wilk, R., Mei, M., Holzwarth, R., Krumbholz, N., & Koch, M. (2010). Optical sampling by laser cavity tuning. Optics Express. https://doi.org/10.1364/oe.18.001613

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.