Enhancement of spectral resolution and accuracy in asynchronous-optical-sampling terahertz time-domain spectroscopy for low-pressure gas-phase analysis
Open accessAbstract
The spectral resolution and accuracy of asynchronous-optical-sampling terahertz time-domain spectroscopy (ASOPS-THz-TDS) were evaluated by examining low-pressure gas-phase samples. Use of dual 56-MHz, erbium (Er)-doped, mode-locked femtosecond fiber lasers enhanced the spectral resolution to as low as 50.5 MHz and the spectral accuracy to as low as 6.2 × 10(-6). The results indicate that ASOPS-THz-TDS has the potential to achieve high spectral resolution, high spectral accuracy, and wide spectral coverage at the same time. ASOPS-THz-TDS will open a new door to gas-phase spectroscopy of multiple chemical species in the field of atmospheric gas analysis.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The use of ASOPS has expanded the target of THz-TDS to substances with narrow spectral lines, such as gas molecules.
“The use of ASOPS has expanded the target of THz-TDS to substances with narrow spectral lines, such as gas molecules [2-4].”
From Jitter correction for asynchronous optical sampling terahertz spectroscopy using free-running pulsed lasers (2023) · cites this paper as [3]
Most ASOPS THz-TDS techniques use IFG, sum-frequency generation, or two-photon absorption of pulsed lasers as a trigger for signal accumulation.
“Most ASOPS THz-TDS techniques use IFG, sum-frequency generation, or twophoton absorption of pulsed lasers as a trigger for signal accumulation [3,11,12,18,31].”
From Jitter correction for asynchronous optical sampling terahertz spectroscopy using free-running pulsed lasers (2023) · cites this paper as [3]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
No citation lists for this paper
No citation lists for this paper yet — checked again daily.
References 17 · Cited by 42
- Authors
- Yasui, T., Kawamoto, K., Hsieh, Y.-D., Sakaguchi, Y., Jewariya, M., Inaba, H., Minoshima, K., Hindle, F., & Araki, T.
- Affiliations
- The University of Osaka (JP)
- Tokushima University (JP)
- National Metrology Institute of Japan (JP)
- Université du littoral côte d'opale (FR)
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2012-06-20
- Volume
- 20
- Issue
- 14
- Pages
- 15071
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2016946385
- Cited by
- 42
- References
- 17
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 1 · 2023: 4 · 2022: 1 · 2021: 3 · 2020: 1 · 2019: 1 · 2018: 4 · 2017: 3 · 2016: 4 · 2015: 2 · 2014: 6 · 2013: 7 · 2012: 2
- FWCI
- 3.48
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Optics Express (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Japan Society for the Promotion of Science (23656265, 23860029)
- RIKEN
- Collaborative Research Based on Industrial Demand
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
- Physical Sciences › Chemistry › Spectroscopy › Spectroscopy and Laser Applications
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
- Keywords
- asynchronous optical sampling, terahertz time-domain spectroscopy, spectral resolution, spectral accuracy, erbium-doped fiber laser, femtosecond mode-locked laser, atmospheric gas analysis, gas-phase spectroscopy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review