Calibration of spatial light modulators suffering from spatially varying phase response
Open accessThe DOI matches its Crossref record.
Abstract
We present a method for converting the desired phase values of a hologram to the correct pixel addressing values of a spatial light modulator (SLM), taking into account detailed spatial variations in the phase response of the SLM. In addition to thickness variations in the liquid crystal layer of the SLM, we also show that these variations in phase response can be caused by a non-uniform electric drive scheme in the SLM or by local heating caused by the incident laser beam. We demonstrate that the use of a global look-up table (LUT), even in combination with a spatially varying scale factor, generally does not yield sufficiently accurate conversion for applications requiring highly controllable output fields, such as holographic optical trapping (HOT). We therefore propose a method where the pixel addressing values are given by a three-dimensional polynomial, with two of the variables being the (x, y)-positions of the pixels, and the third their desired phase values. The coefficients of the polynomial are determined by measuring the phase response in 8 × 8 sub-sections of the SLM surface; the degree of the polynomial is optimized so that the polynomial expression nearly replicates the measurement in the measurement points, while still showing a good interpolation behavior in between. The polynomial evaluation increases the total computation time for hologram generation by only a few percent. Compared to conventional phase conversion methods, for an SLM with varying phase response, we found that the proposed method increases the control of the trap intensities in HOT, and efficiently prevents the appearance of strong unwanted 0th order diffraction that commonly occurs in SLM systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fundamentals of phase-only liquid crystal on silicon (LCOS) devices
Zhang, Z., You, Z., & Chu, D. (2014) · Light: Science & Applications · doi:10.1038/lsa.2014.94 · Cited by 519
Adaptive optics in laser processing
Salter, P. S., & Booth, M. J. (2019) · Light: Science & Applications · doi:10.1038/s41377-019-0215-1 · Cited by 321
Lazarev, G., Chen, P.-J., Strauss, J., Fontaine, N., & Forbes, A. (2019) · Optics Express · doi:10.1364/oe.27.016206 · Cited by 175
Infrared metasurface absorber based on silicon-based CMOS process
Zhang, Y., Wu, Z., Xia, J., Wu, J., Yang, K., Dong, C., Tong, G., Zhang, H., Yang, R., & Luo, Y. (2022) · Optics Express · doi:10.1364/oe.465680 · Cited by 12
Metadata
- Authors
- Engström, D., Persson, M., Bengtsson, J., & Goksör, M.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2013-06-28
- Volume
- 21
- Issue
- 13
- Pages
- 16086
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W1996255498
- Cited by
- 93
- References
- 0
- FWCI
- 11.01
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Calibration of spatial light modulators suffering from spatially varying phase response. https://app.cochat.ai/papers/10.1364/oe.21.016086
- The paper
- Engström, D., Persson, M., Bengtsson, J., & Goksör, M. (2013). Calibration of spatial light modulators suffering from spatially varying phase response. Optics Express. https://doi.org/10.1364/oe.21.016086
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.