Cited by 105Spectroscopy and Laser ApplicationsAdvanced Fiber Laser TechnologiesLaser Design and Applications

Dual electro-optic optical frequency combs for multiheterodyne molecular dispersion spectroscopy

Open access
Martín-Mateos, Pedro, Jerez, Borja, Acedo, Pablo·2015·Optics Express

Abstract

In this paper, a multiheterodyne architecture for molecular dispersion spectroscopy based on a coherent dual-comb source generated using a single continuous wave laser and electro-optic modulators is presented and validated. The phase-sensitive scheme greatly simplifies previous dual-comb implementations by the use of an electro-optic dual comb and by phase-locking all the signal generators of the setup eliminating, in this way, the necessity of any reference optical path currently mandatory in absorption-based instruments. The architecture is immune to the classical baseline and normalization problems of absorption-based analyzers and provides an output linearly dependent on the gas concentration. In addition, the simultaneous parallel multi-wavelength measurement approach has the ability to deliver an improved output bandwidth (measurement speed) over gas analyzers based on tunable lasers.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/oe.23.021149

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • By using the intervals and phases of the IFG, the jitters at the entire time window between the triggers can be corrected using software algorithms, as previously studied in dual-comb spectroscopy.

    “By using the intervals and phases of the IFG, the jitters at the entire time window between the triggers can be corrected using software algorithms, as previously studied in the scheme of dual-comb spectroscopy [33-36].”

    From Jitter correction for asynchronous optical sampling terahertz spectroscopy using free-running pulsed lasers (2023) · cites this paper as [34]

    Section 2.2 (p. 6) describes maintaining phase coherence by phase-locking the oscillators, and Section 3 (p. 8) describes software-based phase measurement. Neither describes using interferogram intervals and phases to correct jitter throughout the time window between triggers. Searches for interferogram timing and software jitter correction found no passage addressing that claim. (LLM, conf=0.76)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 32 · Cited by 105

Research works printed but not linked: 30

  1. [1]1. D. Roschdestwensky, 'Anomale dispersion im natriumdampf,' Ann. Phys. 344 (12), 307-345 (1912).
  2. [2]2. P. van de Weijer and R. M. M. Cremers, 'Hook method: improvement and simplification of the experimental setup,' Appl. Opt. 22 (22), 3500-3502 (1983).
  3. [4]4. R. Gross, R. Chodzko, E. Turner, and J. Coffer, 'Measurements of the anomalous dispersion of HF in absorption,' IEEE J. Quantum Electron. 16 (7), 795-798 (1980).
  4. [3]3. E. Kindel, M. Kettlitz, C. Schimke, and H. Schöpp, 'Application of the hook method and emission spectroscopy for the determination of radial density and temperature profiles in high-pressure mercury discharges,' J. Phys. D Appl. Phys. 31 (11), 1352-1361 (1998).
  5. [5]5. A. B. Duval and A. I. McIntosh, 'Measurement of oscillator strength by tunable laser interferometry,' J. Phys. D Appl. Phys. 13 (9), 1617-1624 (1980).
  6. [6]6. S. Marchetti and R. Simili, 'Measurement of the refractive index dispersion around an absorbing line,' Opt. Commun. 249 (1-3), 37-41 (2005).
  7. [7]7. A. J. Kemp, J. R. Birch, and M. N. Afsar, 'The refractive index of water vapour: a comparison of measurement and theory,' Infrared Phys. 18 (5-6), 827-833 (1978).
  8. [8]8. J. R. Birch and M. N. Afsar, 'The rotation spectrum of methyl alcohol vapour between 8 and 50 cm -1 ,' Spectrochim. Acta, Part A 35 (6), 669-672 (1979).
  9. [9]9. J. R. Birch, 'Recent progress in dispersive fourier transform spectrometry,' Proc. SPIE 0289 , 362-384 (1981).
  10. [10]10. G. C. Bjorklund, 'Frequency-modulation spectroscopy: a new method for measuring weak absorptions and dispersions,' Opt. Lett. 5 (1), 15-17 (1980).
  11. [11]11. J. A. Silver, 'Frequency-modulation spectroscopy for trace species detection: theory and comparison among experimental methods,' Appl. Opt. 31 (6), 707-717 (1992).
  12. [12]12. M. Gehrtz, G. C. Bjorklund, and E. A. Whittaker, 'Quantum-limited laser frequency-modulation spectroscopy,' J. Opt. Soc. Am. B 2 (9), 1510-1526 (1985).
  13. [13]13. G. Wysocki and D. Weidmann, 'Molecular dispersion spectroscopy for chemical sensing using chirped midinfrared quantum cascade laser,' Opt. Express 18 (25), 26123-26140 (2010).
  14. [14]14. M. Nikodem and G. Wysocki, 'Chirped laser dispersion spectroscopy for remote open-path trace-gas sensing,' Sensors (Basel) 12 (12), 16466-16481 (2012).
  15. [15]15. P. Martín-Mateos and P. Acedo, 'Heterodyne phase-sensitive detection for calibration-free molecular dispersion spectroscopy,' Opt. Express 22 (12), 15143-15153 (2014).
  16. [16]16. E. Baumann, F. R. Giorgetta, W. C. Swann, A. M. Zolot, I. Coddington, and N. R. Newbury, 'Spectroscopy of the methane ν 3 band with an accurate midinfrared coherent dual-comb spectrometer,' Phys. Rev. A 84 (6), 062513 (2011).
  17. [18]18. M. Niering, R. Holzwarth, J. Reichert, P. Pokasov, T. Udem, M. Weitz, T. W. Hansch, P. Lemonde, G. Santarelli, M. Abgrall, P. Laurent, C. Salomon, and A. Clairon, 'Measurement of the hydrogen 1S- 2S transition frequency by phase coherent comparison with a microwave cesium fountain clock,' Phys. Rev. Lett. 84 (24), 5496-5499 (2000).
  18. [19]19. S. Schiller, 'Spectrometry with frequency combs,' Opt. Lett. 27 (9), 766-768 (2002).
  19. [22]22. M. J. Thorpe, K. D. Moll, R. J. Jones, B. Safdi, and J. Ye, 'Broadband cavity ringdown spectroscopy for sensitive and rapid molecular detection,' Science 311 (5767), 1595-1599 (2006).
  20. [23]23. B. Bernhardt, A. Ozawa, P. Jacquet, M. Jacquey, Y. Kobayashi, T. Udem, R. Holzwarth, G. Guelachvili, T. W. Hänsch, and N. Picqué, 'Cavity-enhanced dual-comb spectroscopy,' Nat. Photonics 4 (1), 55-57 (2010).
  21. [24]24. A. Schliesser, M. Brehm, F. Keilmann, and D. van der Weide, 'Frequency-comb infrared spectrometer for rapid, remote chemical sensing,' Opt. Express 13 (22), 9029-9038 (2005).
  22. [25]25. B. R. Washburn, W. C. Swann, and N. R. Newbury, 'Response dynamics of the frequency comb output from a femtosecond fiber laser,' Opt. Express 13 (26), 10622-10633 (2005).
  23. [26]26. T. Sakamoto, T. Kawanishi, and M. Izutsu, 'Widely wavelength-tunable ultra-flat frequency comb generation using conventional dual-drive Mach-Zehnder modulator,' Electron. Lett. 43 (19), 1039 (2007).
  24. [27]27. D. A. Long, A. J. Fleisher, K. O. Douglass, S. E. Maxwell, K. Bielska, J. T. Hodges, and D. F. Plusquellic, 'Multiheterodyne spectroscopy with optical frequency combs generated from a continuous-wave laser,' Opt. Lett. 39 (9), 2688-2690 (2014).
  25. [28]28. P. Martin-Mateos, M. Ruiz-Llata, J. Posada-Roman, and P. Acedo, 'Dual comb architecture for fast spectroscopic measurements and spectral characterization,' IEEE Photonics Technol. Lett. 27 (12), 1309-1312 (2015).
  26. [29]29. D. P. Blair and P. H. Sydenham, 'Phase sensitive detection as a means to recover signals buried in noise,' J. Phys. Educ. 8 (8), 621-627 (1975).
  27. [31]31. J. Irby, R. Murray, P. Acedo, and H. Lamela, 'A two-color interferometer using a frequency doubled diode pumped laser for electron density measurements,' Rev. Sci. Instrum. 70 (1), 699-702 (1999).
  28. [30]30. P. Martín-Mateos, S. Crespo-Garcia, M. Ruiz-Llata, J. R. Lopez-Fernandez, J. L. Jorcano, M. Del Rio, F. Larcher, and P. Acedo, 'Remote diffuse reflectance spectroscopy sensor for tissue engineering monitoring based on blind signal separation,' Biomed. Opt. Express 5 (9), 3231-3237 (2014).
  29. [32]32. N. R. Newbury, I. Coddington, and W. Swann, 'Sensitivity of coherent dual-comb spectroscopy,' Opt. Express 18 (8), 7929-7945 (2010).
  30. [34]34. P. Martín-Mateos, B. Jerez, and P. Acedo, 'Heterodyne architecture for tunable laser chirped dispersion spectroscopy using optical processing,' Opt. Lett. 39 (9), 2611-2613 (2014).

Authors
Martín-Mateos, P., Jerez, B., & Acedo, P.
Affiliations
Universidad Carlos III de Madrid (ES)
Venue
Optics Express
Published
2015-08-04
Volume
23
Issue
16
Pages
21149
ISSN
1094-4087 (ISSN-L)
OpenAlex
W2466950167
Cited by
105
References
32
Citations by year
2026: 2 · 2025: 3 · 2024: 5 · 2023: 10 · 2022: 9 · 2021: 9 · 2020: 15 · 2019: 9 · 2018: 15 · 2017: 12 · 2016: 15 · 2015: 1
FWCI
6.38
Type
journal article
Language
en
Open access
Locations
  • Optics Express (publishedVersion)
  • PubMed (publishedVersion)
  • e-Archivo (Carlos III University of Madrid) (submittedVersion, other-oa)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Spectroscopy and Laser Applications
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Fiber Laser Technologies
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Laser Design and Applications
Keywords
dual-comb spectroscopy, electro-optic modulator, phase-sensitive detection, phase locking, gas concentration measurement, multi-wavelength measurement, continuous-wave laser, optical frequency combs

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review