Surface plasmon resonance biosensor based on gold-coated side-polished hexagonal structure photonic crystal fiber
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
The refractive index sensing characteristics of the side-polished photonic crystal fiber (PCF) surface plasmon resonance (SPR) sensor are detailed investigated in this paper. We used the finite element method (FEM) to study the influences of the side-polished depth, air hole size, lattice constant, and the refractive index (RI) of the PCF material on sensing performance. The simulation results show that the side-polished depth, air hole size, lattice pitch have significant influence on the coupling strength between core mode and surface plasmon polaritons (SPPs), but have little influence on sensitivity; the coupling strength and sensitivity will significant increase with the decrease of RI of the PCF material. The sensitivity of the D-shaped PCF sensor is obtained to be as high as 21700 nm/RIU in the refractive index environment of 1.33-1.34, when the RI of the PCF material is controlled at 1.36. It revealed a new method of making ultra-high sensitivity SPR fiber sensor. Then we experimental demonstrated a SPR refractive sensor based on the side-polished single mode PCF and investigated the sensing performance. The experimental results of the plasmon resonance wavelength sensitivity agree well with the theoretical results. The presented gold-coated D-shaped PCF SPR sensor could be used as a simple, cost-effective, high sensitivity device in bio-chemical detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical Constants of the Noble Metals
Johnson, P. B., & Christy, R. W. (1972) · Physical Review B · doi:10.1103/physrevb.6.4370 · Cited by 20,094
A fiber-optic chemical sensor based on surface plasmon resonance
Jorgenson, R. C., & Yee, S. S. (1993) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(93)80021-3 · Cited by 1,229
Current status of micro- and nano-structured optical fiber sensors
Lee, B., Roh, S., & Park, J. (2009) · Optical Fiber Technology · doi:10.1016/j.yofte.2009.02.006 · Cited by 373
Determination of refractive index of silica glass for infrared wavelengths by IR spectroscopy
Tan, C. Z. (1998) · Journal of Non-Crystalline Solids · doi:10.1016/s0022-3093(97)00438-9 · Cited by 352
Design criteria for microstructured-optical-fiber-based surface-plasmon-resonance sensors
Hassani, A., & Skorobogatiy, M. (2007) · Journal of the Optical Society of America B · doi:10.1364/josab.24.001423 · Cited by 310
Photonic crystal fiber based surface plasmon resonance chemical sensors
Zhao, Y., Deng, Z.-Q., & Li, J. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.05.127 · Cited by 207
Suzuki, H., Sugimoto, M., Matsui, Y., & Kondoh, J. (2008) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2008.01.003 · Cited by 168
Graphene-Based Conducting Metal Oxide Coated D-Shaped Optical Fiber SPR Sensor
Patnaik, A., Senthilnathan, K., & Jha, R. (2015) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2015.2467189 · Cited by 157
Metadata
- Authors
- Wu, T., Shao, Y., Wang, Y., Cao, S., Cao, W., Zhang, F., Liao, C., He, J., Huang, Y., Hou, M., & Wang, Y.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2017-08-11
- Volume
- 25
- Issue
- 17
- Pages
- 20313
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2743934085
- Cited by
- 237
- References
- 8
- FWCI
- 8.28
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.