Cited by 23Terahertz technology and applicationsHydrocarbon exploration and reservoir analysisThermography and Photoacoustic Techniques

Terahertz scattering and water absorption for porosimetry

Open access
Heshmat, Barmak, Andrews, Gordon Moseley, Naranjo-Montoya, Oscar A., Castro-Camus, Enrique, Ciceri, Davide, Sanchez, Albert Redo, Allanore, Antoine, Kmetz, Anthony A. +3 more·2017·Optics Express

Abstract

We use terahertz transmission through limestone sedimentary rock samples to assess the macro and micro porosity. We exploit the notable water absorption in the terahertz spectrum to interact with the pores that are two orders of magnitude smaller (<1μm) than the terahertz wavelength. Terahertz water sensitivity provides us with the dehydration profile of the rock samples. The results show that there is a linear correlation between such a profile and the ratio of micro to macro porosity of the rock. Furthermore, this study estimates the absolute value of total porosity based on optical diffusion theory. We compare our results with that of mercury injection capillary pressure as a benchmark to confirm our analytic framework. The porosimetry method presented here sets a foundation for a new generation of less invasive porosimetry methods with higher penetration depth based on lower frequency (f<10THz) scattering and absorption. The technique has applications in geological studies and in other industries without the need for hazardous mercury or ionizing radiation.

Integrity signals

Registry

Crossref · 10.1364/oe.25.027370

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Total porosity can be calculated from a THz-TDS measurement by using effective medium theory and knowing the intrinsic refractive index of the solid matrix.

    “The total porosity can thus be calculated from a THz-TDS measurement by utilizing effective medium theory and knowing the intrinsic refractive index of the solid matrix.”
  • THz-TDS has been demonstrated to measure porosity of rocks and pharmaceutical tablets and to analyze anisotropy of pore structures.

    “This method has been demonstrated to measure the porosity of rocks [20] and pharmaceutical tablets [21,22,23] as well as to analyze the anisotropy of pore structures [18,24].”

The citation lists haven’t been fetched yet

References 52 · Cited by 23

Authors
Heshmat, B., Andrews, G. M., Naranjo-Montoya, O. A., Castro-Camus, E., Ciceri, D., Sanchez, A. R., Allanore, A., Kmetz, A. A., Eichmann, S. L., Poitzsch, M. E., & Raskar, R.
Venue
Optics Express
Published
2017-10-24
Volume
25
Issue
22
Pages
27370
ISSN
1094-4087 (ISSN-L)
OpenAlex
W2765473451
Cited by
23
References
52
Citations by year
2026: 3 · 2025: 1 · 2024: 5 · 2023: 1 · 2022: 2 · 2021: 2 · 2020: 3 · 2019: 5 · 2018: 1
FWCI
1.02
Type
journal article
Language
en
Open access
Locations
  • Optics Express (publishedVersion)
  • PubMed (publishedVersion)
  • DSpace@MIT (Massachusetts Institute of Technology) (submittedVersion, cc-by-nc)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
  • Physical Sciences › Engineering › Mechanics of Materials › Hydrocarbon exploration and reservoir analysis
  • Physical Sciences › Engineering › Mechanics of Materials › Thermography and Photoacoustic Techniques
Keywords
terahertz scattering, water absorption, porosimetry, limestone, sedimentary rock, microporosity, macroporosity, mercury injection capillary pressure, terahertz transmission

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review