2D material assisted SMF-MCF-MMF-SMF based LSPR sensor for creatinine detection
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The purpose of this work is to propose a simple, portable, and sensitive biosensor structure based on singlemode fiber-multicore fiber-multimode fiber-singlemode fiber (SMF-MCF-MMF-SMF) for the detection of creatinine in the human body. Chemical etching has been used to modify the diameter of the sensing probe to approximately 90 μm in order to generate strong evanescent waves (EWs). The sensor probe is functionalized with graphene oxide (GO), gold nanoparticles (AuNPs), molybdenum disulfide nanoparticles (MoS 2-NPs), and creatininase (CA) enzyme. The concentration of creatinine is determined using fiber optic localized surface plasmon resonance (LSPR). While EWs are used to enhance the LSPR effect of AuNPs, two-dimensional (2D) materials (GO and MoS 2-NPs) are used to increase biocompatibility, and CA is used to increase probe specificity. Additionally, HR-TEM and UV-visible spectroscopy are used to characterize and measure the nanoparticle (NP) morphology and absorption spectrum, respectively. SEM is used to characterize the NPs immobilized on the surface of the fiber probe. The sensor probe's reusability, reproducibility, stability, selectivity, and pH test results are also tested to verify the sensor performance. The sensitivity of proposed sensor is 0.0025 nm/μM, has a standard deviation of 0.107, and has a limit of detection of 128.4 μM over a linear detection range of 0 - 2000 μM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smith, A. T., LaChance, A. M., Zeng, S., Liu, B., & Sun, L. (2019) · Nano Materials Science · doi:10.1016/j.nanoms.2019.02.004 · Cited by 1,643
Cited by
Recent Advancements of LSPR Fiber‐Optic Biosensing: Combination Methods, Structure, and Prospects
Zhang, H., Zhou, X., Li, X., Gong, P., Zhang, Y., & Zhao, Y. (2023) · Biosensors · doi:10.3390/bios13030405 · Cited by 99
“The excited mode is extremely sensitive to changes in the surrounding environment of the MCF cladding, resulting in an ultrasensitive sensor [97].”
Background
Metadata
- Authors
- Li, M., Singh, R., Marques, C., Zhang, B., & Kumar, S.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2021-11-01
- Volume
- 29
- Issue
- 23
- Pages
- 38150
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W3209861045
- Cited by
- 176
- References
- 1
- FWCI
- 10.73
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 2D material assisted SMF-MCF-MMF-SMF based LSPR sensor for creatinine detection. https://app.cochat.ai/papers/10.1364/oe.445555
- The paper
- Li, M., Singh, R., Marques, C., Zhang, B., & Kumar, S. (2021). 2D material assisted SMF-MCF-MMF-SMF based LSPR sensor for creatinine detection. Optics Express. https://doi.org/10.1364/oe.445555
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.