Cited by 18Atomic and Subatomic Physics ResearchMechanical and Optical ResonatorsMagnetic Field Sensors Techniques

Four-channel optically pumped magnetometer for a magnetoencephalography sensor array

Open access
Iivanainen, Joonas, Carter, Tony R., Dhombridge, Jonathan E., Read, Timothy S., Campbell, Kaleb, Abate, Quinn, Ridley, David M., Borna, Amir +1 more·2024·Optics Express

Abstract

We present a novel four-channel optically pumped magnetometer (OPM) for magnetoencephalography that utilizes a two-color pump/probe scheme on a single optical axis. We characterize its performance across 18 built sensor modules. The new sensor implements several improvements over our previously developed sensor including lower vapor-cell operating temperature, improved probe-light detection optics, and reduced optical power requirements. The sensor also has new electromagnetic field coils on the sensor head which are designed using stream-function-based current optimization. We detail the coil design methodology and present experimental characterization of the coil performance. The magnetic sensitivity of the sensor is on average 12.3 fT/rt-Hz across the 18 modules while the average gradiometrically inferred sensitivity is about 6.0 fT/rt-Hz. The sensor 3-dB bandwidth is 100 Hz on average. The on-sensor coil performance is in good agreement with the simulations.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/oe.517961

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 50 · Cited by 18

Research works printed but not linked: 1

  1. [33]Johnson C. Schwindt P.D., “ A two-color pump probe atomic magnetometer for magnetoencephalography,” in 2010 IEEE International Frequency Control Symposium. 2010. IEEE.

Authors
Iivanainen, J., Carter, T. R., Dhombridge, J. E., Read, T. S., Campbell, K., Abate, Q., Ridley, D. M., Borna, A., & Schwindt, P. D. D.
Affiliations
  • Sandia National Laboratories (US)
  • University of New Mexico (US)
Corresponding author
Schwindt, Peter D. D.
Venue
Optics Express
Published
2024-05-03
Volume
32
Issue
10
Pages
18334
ISSN
1094-4087 (ISSN-L)
OpenAlex
W4394998221
Cited by
18
References
50
Citations by year
2026: 6 · 2025: 7 · 2024: 5
FWCI
2.85
Type
journal article
Language
en
Open access
Locations
  • Optics Express (publishedVersion)
  • PubMed Central (publishedVersion)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed (publishedVersion)
  • OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
Funders
  • National Institute of Biomedical Imaging and Bioengineering (U01EB028656)
  • Sandia National Laboratories
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Mechanical and Optical Resonators
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
Keywords
optically pumped magnetometers, magnetoencephalography, sensor arrays, two-color pump-probe, vapor cell, magnetic field coils, magnetic field sensitivity, 3-dB bandwidth

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review