The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Medical image fusion by wavelet transform modulus maxima
Open accessAbstract
Medical image fusion has been used to derive useful information from multimodality medical image data. In this research, we propose a novel method for multimodality medical image fusion. Using wavelet transform, we achieved a fusion scheme. Afusion rule is proposed and used for calculating the wavelet transformation modulus maxima of input images at different bandwidths and levels. To evaluate the fusion result, a metric based on mutual information (MI) is presented for measuring fusion effect. The performances of other two methods of image fusion based on wavelet transform are briefly described for comparison. The experiment results demonstrate the effectiveness of the fusion scheme.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Laplacian pyramid as a compact image code
Burt, P., & Adelson, E. (1983) · IEEE Transactions on Communications · doi:10.1109/tcom.1983.1095851 · Cited by 6,077
A survey of image registration techniques
Brown, L. G. (1992) · ACM Computing Surveys · doi:10.1145/146370.146374 · Cited by 4,057
Characterization of signals from multiscale edges
Mallat, S., & Zhong, S. (1992) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.142909 · Cited by 3,200
Entropy-based algorithms for best basis selection
Coifman, R. R., & Wickerhauser, M. V. (1992) · IEEE Transactions on Information Theory · doi:10.1109/18.119732 · Cited by 3,188
Multi-sensor image fusion using the wavelet transform
Li, H., Manjunath, B. S., & Mitra, S. K. (2002) · Proceedings of 1st International Conference on Image Processing · doi:10.1109/icip.1994.413273 · Cited by 1,513
Medical image matching-a review with classification
van den Elsen, P. A., Pol, E.-J. D., & Viergever, M. A. (1993) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.195938 · Cited by 718
Cited by
Medical image fusion: A survey of the state of the art
James, A. P., & Dasarathy, B. V. (2014) · Information Fusion · doi:10.1016/j.inffus.2013.12.002 · Cited by 967
A new quality metric for image fusion
Piella, G., & Heijmans, H. (2004) · Proceedings 2003 International Conference on Image Processing (Cat. No.03CH37429) · doi:10.1109/icip.2003.1247209 · Cited by 838
Cui, G., Feng, H., Xu, Z., Li, Q., & Chen, Y. (2015) · Optics Communications · doi:10.1016/j.optcom.2014.12.032 · Cited by 612
Image fusion based on pixel significance using cross bilateral filter
Shreyamsha Kumar, B. K. (2015) · Signal, Image and Video Processing · doi:10.1007/s11760-013-0556-9 · Cited by 567
Directive Contrast Based Multimodal Medical Image Fusion in NSCT Domain
Bhatnagar, G., Wu, Q. M. J., & Liu, Z. (2013) · IEEE Transactions on Multimedia · doi:10.1109/tmm.2013.2244870 · Cited by 471
Metadata
- Authors
- Guihong, Q., Dali, Z., & Pingfan, Y.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2001-08-13
- Volume
- 9
- Issue
- 4
- Pages
- 184
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2044867573
- Cited by
- 252
- References
- 6
- FWCI
- 4.19
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Medical image fusion by wavelet transform modulus maxima. https://app.cochat.ai/papers/10.1364/oe.9.000184
- The paper
- Guihong, Q., Dali, Z., & Pingfan, Y. (2001). Medical image fusion by wavelet transform modulus maxima. Optics Express. https://doi.org/10.1364/oe.9.000184
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.