The DOI matches its Crossref record.
Two-wavelength laser interferometry using superheterodyne detection
Open accessAbstract
In two-wavelength interferometry, synthetic wavelengths are generated in order to reduce the sensitivity or to extend the range of unambiguity for interferometric measurements. Here a novel optoelectronic technique, called superheterodyne detection, is presented, which permits measurement of the phase difference of two optical frequencies that cannot be resolved by direct optoelectronic heterodyne detection. This technique offers the possibility for operation of two-wavelength interferometry in real time with arbitrary synthetic wavelengths from micrometers to meters in length. Preliminary experimental results are reported. An optical arrangement for absolute range-finding applications using tunable-laser sources (e.g., semiconductor lasers) is proposed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rapid and precise absolute distance measurements at long range
Coddington, I., Swann, W. C., Nenadovic, L., & Newbury, N. R. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.94 · Cited by 1,059
Absolute measurement of a long, arbitrary distance to less than an optical fringe
Ye, J. (2004) · Optics Letters · doi:10.1364/ol.29.001153 · Cited by 337
Motazedifard, A., Madani, S. A., Dashkasan, J. J., & Vayaghan, N. S. (2021) · Heliyon · doi:10.1016/j.heliyon.2021.e07384 · Cited by 23
Metadata
- Authors
- Dändliker, R., Thalmann, R., & Prongué, D.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 1988-05-01
- Volume
- 13
- Issue
- 5
- Pages
- 339
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W1985653392
- Cited by
- 240
- References
- 0
- FWCI
- 5.65
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Two-wavelength laser interferometry using superheterodyne detection. https://app.cochat.ai/papers/10.1364/ol.13.000339
- The paper
- Dändliker, R., Thalmann, R., & Prongué, D. (1988). Two-wavelength laser interferometry using superheterodyne detection. Optics Letters. https://doi.org/10.1364/ol.13.000339
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.