Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 2,652

The DOI matches its Crossref record.

High-sensitivity, single-beam n_2 measurements

Open access
Sheik-bahae, M., Said, A. A., Van Stryland, E. W.·1989·Optics Letters

Abstract

We present a simple yet highly sensitive single-beam experimental technique for the determination of both the sign and magnitude of n(2). The sample is moved along the z direction of a focused Gaussian beam while the repetitively pulsed laser energy is held fixed. The resultant plot of transmittance through an aperture in the far field yields a dispersion-shaped curve from which n(2) is easily calculated. A transmittance change of 1% corresponds to a phase distortion of approximately lambda/250. We demonstrate this method on several materials using both CO(2) and Nd:YAG laser pulses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/ol.14.000955

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 2,652

Metadata

Authors
Sheik-bahae, M., Said, A. A., & Van Stryland, E. W.
Venue
Optics Letters
Published
1989-09-01
Volume
14
Issue
17
Pages
955
ISSN
  • 0146-9592 (ISSN-L)
  • 1539-4794
OpenAlex
W2125097568
Cited by
2,652
References
0
FWCI
23.32
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-sensitivity, single-beam n_2 measurements. https://app.cochat.ai/papers/10.1364/ol.14.000955
The paper
Sheik-bahae, M., Said, A. A., & Van Stryland, E. W. (1989). High-sensitivity, single-beam n_2 measurements. Optics Letters. https://doi.org/10.1364/ol.14.000955

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.