The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Multiplexed fiber Bragg grating strain-sensor system with a fiber Fabry–Perot wavelength filter
Abstract
The use of a fiber Fabry–Perot filter for detecting the wavelength shift of a fiber Bragg grating sensor or network of sensor elements along a commonfiber path is described. Results obtained by using a system with four sensor elements are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Formation of Bragg gratings in optical fibers by a transverse holographic method
Meltz, G., Morey, W. W., & Glenn, W. H. (1989) · Optics Letters · doi:10.1364/ol.14.000823 · Cited by 1,808
Self-citationFiber-optic Bragg-grating differential-temperature sensor
Kersey, A. D., & Berkoff, T. A. (1992) · IEEE Photonics Technology Letters · doi:10.1109/68.163773 · Cited by 121
Self-citation
Cited by
Kersey, A. D., Davis, M. A., Patrick, H. J., LeBlanc, M., Koo, K. P., Askins, C. G., Putnam, M. A., & Friebele, E. J. (1997) · Journal of Lightwave Technology · doi:10.1109/50.618377 · Cited by 3,599
Self-citationReview of the present status of optical fiber sensors
Lee, B. (2003) · Optical Fiber Technology · doi:10.1016/s1068-5200(02)00527-8 · Cited by 1,736
In-fibre Bragg grating sensors
Rao, Y.-J. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/4/002 · Cited by 1,606
Fibre Bragg gratings in structural health monitoring—Present status and applications
Majumder, M., Gangopadhyay, T. K., Chakraborty, A. K., Dasgupta, K., & Bhattacharya, D. K. (2008) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2008.04.008 · Cited by 973
Di Sante, R. (2015) · Sensors · doi:10.3390/s150818666 · Cited by 684
Metadata
- Authors
- Kersey, A. D., Berkoff, T. A., & Morey, W. W.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 1993-08-15
- Volume
- 18
- Issue
- 16
- Pages
- 1370
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2065640199
- Cited by
- 678
- References
- 2
- FWCI
- 14.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.