The DOI matches its Crossref record.
Hyperfine structure and absolute frequency of the ^87Rb 5P_3/2 state
Abstract
We have constructed two highly stable and reproducible (87)Rb D(2)-saturated-absorption spectrometers at 780 nm, using dither/third-harmonic lock-in detection and radio-frequency sideband techniques, respectively. We achieved +/-3-kHz reproducibility and agreement between these two independent systems. Heterodyne measurements of the hyperfine splittings of the 5P(3/2) state give its magnetic dipole (A) and electric quadrupole (B) hyperfine constants with a 10-fold reduction in uncertainty.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
United Time-Frequency Spectroscopy for Dynamics and Global Structure
Marian, A., Stowe, M. C., Lawall, J. R., Felinto, D., & Ye, J. (2004) · Science · doi:10.1126/science.1105660 · Cited by 294
Self-citationThe CIPM list of recommended frequency standard values: guidelines and procedures
Riehle, F., Gill, P., Arias, F., & Robertsson, L. (2018) · Metrologia · doi:10.1088/1681-7575/aaa302 · Cited by 281
Metadata
- Authors
- Ye, J., Swartz, S., Jungner, P., & Hall, J. L.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 1996-08-15
- Volume
- 21
- Issue
- 16
- Pages
- 1280
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2104117801
- Cited by
- 237
- References
- 0
- FWCI
- 3.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hyperfine structure and absolute frequency of the ^87Rb 5P_3/2 state. https://app.cochat.ai/papers/10.1364/ol.21.001280
- The paper
- Ye, J., Swartz, S., Jungner, P., & Hall, J. L. (1996). Hyperfine structure and absolute frequency of the ^87Rb 5P_3/2 state. Optics Letters. https://doi.org/10.1364/ol.21.001280
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.