The DOI matches its Crossref record.
Sub-8-fs pulses from an ultrabroadband optical parametric amplifier in the visible
Abstract
Pulses with 180-THz bandwidth and 2-microJ energy were generated by a noncollinear optical parametric amplifier in the visible, pumped by the second harmonic of a Ti:sapphire laser. A portion of the amplified pulse spectrum was compressed to 7.2 fs by use of a thin prism sequence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Krausz, F., & Ivanov, M. (2009) · Reviews of Modern Physics · doi:10.1103/revmodphys.81.163 · Cited by 5,468
Ultrafast optical parametric amplifiers
Cerullo, G., & De Silvestri, S. (2003) · Review of Scientific Instruments · doi:10.1063/1.1523642 · Cited by 965
Self-citationPhotosynthetic Light Harvesting by Carotenoids: Detection of an Intermediate Excited State
Cerullo, G., Polli, D., Lanzani, G., De Silvestri, S., Hashimoto, H., & Cogdell, R. J. (2002) · Science · doi:10.1126/science.1074685 · Cited by 258
Self-citationThe effect of the Gouy phase in optical-pump-THz-probe spectroscopy
Ahmed, S., Savolainen, J., & Hamm, P. (2014) · Optics Express · doi:10.1364/oe.22.004256 · Cited by 16
Metadata
- Authors
- Cerullo, G., Nisoli, M., Stagira, S., & De Silvestri, S.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 1998-08-15
- Volume
- 23
- Issue
- 16
- Pages
- 1283
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2037648231
- Cited by
- 263
- References
- 0
- FWCI
- 13.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sub-8-fs pulses from an ultrabroadband optical parametric amplifier in the visible. https://app.cochat.ai/papers/10.1364/ol.23.001283
- The paper
- Cerullo, G., Nisoli, M., Stagira, S., & De Silvestri, S. (1998). Sub-8-fs pulses from an ultrabroadband optical parametric amplifier in the visible. Optics Letters. https://doi.org/10.1364/ol.23.001283
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.