The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Pulse-front-matched optical parametric amplification for sub-10-fs pulse generation tunable in the visible and near infrared
Abstract
A noncollinear optical parametric amplifier is presented that generates transform-limited sub-10-fs pulses that are tunable in both the visible and the near infrared (NIR). The pulse-front-matched pump geometry realizes tilt-free signal amplification, and pulses as short as 6.1 fs can be obtained from 550 to 700 nm. The large angular dispersion of the idler specific to the group-velocity-matching interaction is effectively eliminated by a grating-telescope compensator, and 9-fs NIR pulses are also successfully obtained from 900 to 1300 nm. This is believed to be the first tunable sub-10-fs light source.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Compression of optical pulses to six femtoseconds by using cubic phase compensation
Fork, R. L., Brito Cruz, C. H., Becker, P. C., & Shank, C. V. (1987) · Optics Letters · doi:10.1364/ol.12.000483 · Cited by 936
Vibrationally Coherent Photochemistry in the Femtosecond Primary Event of Vision
Wang, Q., Schoenlein, R. W., Peteanu, L. A., Mathies, R. A., & Shank, C. V. (1994) · Science · doi:10.1126/science.7939680 · Cited by 636
Wilhelm, T., Piel, J., & Riedle, E. (1997) · Optics Letters · doi:10.1364/ol.22.001494 · Cited by 563
Sub-20-fs tunable pulses in the visible from an 82-MHz optical parametric oscillator
Gale, G. M., Cavallari, M., Driscoll, T. J., & Hache, F. (1995) · Optics Letters · doi:10.1364/ol.20.001562 · Cited by 221
Self-starting 65-fs pulses from a Ti:sapphire laser
Jung, I. D., Kärtner, F. X., Matuschek, N., Sutter, D. H., Morier-Genoud, F., Zhang, G., Keller, U., Scheuer, V., Tilsch, M., & Tschudi, T. (1997) · Optics Letters · doi:10.1364/ol.22.001009 · Cited by 200
Pulse distortions in tilted pulse schemes for ultrashort pulses
Martinez, O. E. (1986) · Optics Communications · doi:10.1016/0030-4018(86)90290-7 · Cited by 175
Bor, Z., & Rácz, B. (1985) · Optics Communications · doi:10.1016/0030-4018(85)90284-6 · Cited by 175
Generation of 11 fs pulses tunable across the visible by optical parametric amplification
Cerullo, G., Nisoli, M., & De Silvestri, S. (1997) · Applied Physics Letters · doi:10.1063/1.120458 · Cited by 166
Noncollinearly phase-matched femtosecond optical parametric amplification with a 2000 cm−1 bandwidth
Shirakawa, A., & Kobayashi, T. (1998) · Applied Physics Letters · doi:10.1063/1.120670 · Cited by 146
Self-citation
Cited by
Krausz, F., & Ivanov, M. (2009) · Reviews of Modern Physics · doi:10.1103/revmodphys.81.163 · Cited by 5,468
Ultrafast optical parametric amplifiers
Cerullo, G., & De Silvestri, S. (2003) · Review of Scientific Instruments · doi:10.1063/1.1523642 · Cited by 965
Real-time spectroscopy of transition states in bacteriorhodopsin during retinal isomerization
Kobayashi, T., Saito, T., & Ohtani, H. (2001) · Nature · doi:10.1038/35107042 · Cited by 399
Self-citationShirakawa, A., Sakane, I., Takasaka, M., & Kobayashi, T. (1999) · Applied Physics Letters · doi:10.1063/1.123820 · Cited by 333
Self-citation
Metadata
- Authors
- Shirakawa, A., Sakane, I., & Kobayashi, T.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 1998-08-15
- Volume
- 23
- Issue
- 16
- Pages
- 1292
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W1993449728
- Cited by
- 253
- References
- 9
- FWCI
- 10.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.