CoChat

Accuracy of optical frequency comb generators and optical frequency interval divider chains

Udem, Th., Reichert, J., Hänsch, T. W., Kourogi, M. · 1998 · Optics Letters
Cited by 55

The DOI matches its Crossref record.

Abstract

We compared two methods for measuring large optical frequency differences: an optical frequency comb generator, which creates a large number of sidebands from a single-mode laser through electro-optic modulation, and an optical frequency interval divider chain, which divides a frequency gap successively by two until it becomes accessible to a radio-frequency counter. By locking two diode lasers to two modulation sidebands of a comb generator, ~1 THz apart, and measuring this interval with a chain of four phase-locked interval dividers, we demonstrate for the first time to our knowledge the accuracy of both techniques within an experimental limit of 6.8 x 10(-15).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/ol.23.001387

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 55

Metadata

Authors
Udem, T., Reichert, J., Hänsch, T. W., & Kourogi, M.
Venue
Optics Letters
Published
1998-09-01
Volume
23
Issue
17
Pages
1387
ISSN
  • 0146-9592 (ISSN-L)
  • 1539-4794
OpenAlex
W1977840338
Cited by
55
References
0
FWCI
2.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of optical frequency comb generators and optical frequency interval divider chains. https://app.cochat.ai/papers/10.1364/ol.23.001387
The paper
Udem, T., Reichert, J., Hänsch, T. W., & Kourogi, M. (1998). Accuracy of optical frequency comb generators and optical frequency interval divider chains. Optics Letters. https://doi.org/10.1364/ol.23.001387

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.