The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Nanodissection of human chromosomes with near-infrared femtosecond laser pulses
Abstract
Near-infrared laser pulses of a compact 80-MHz femtosecond laser source at 800 nm, a mean power of 15-100 mW, 170-fs pulse width, and millisecond beam dwell times at the target have been used for multiphoton-mediated nanoprocessing of human chromosomes. By focusing of the laser beam with high-numerical-aperture objectives of a scanning microscope to diffraction-limited spots and with light intensities of terawatts per cubic centimeter, precise submicrometer holes and cuts in human chromosomes have been processed by single-point exposure and line scans. A minimum FWHM cut size of ~100 nm during a partial dissection of chromosome 1, which is below the diffraction-limited spot size, and a minimum material removal of ~0.003mum (3) were determined by a scanning-force microscope. The plasma-induced ablated material corresponds to ~1/400 of the chromosome 1 volume and to ~65x10(3) base pairs of chromosomal DNA. A complete dissection could be performed with FWHM cut sizes below 200 nm. High-repetition-frequency femtosecond lasers at low mean power in combination with high-numerical-aperture focusing optics appear therefore as appropriate noncontact tools for nanoprocessing of bulk and (or) surfaces of transparent materials such as chromosomes. In particular, the noninvasive inactivation of certain genomic regions on single chromosomes within living cells becomes possible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Noack, J., & Vogel, A. (1999) · IEEE Journal of Quantum Electronics · doi:10.1109/3.777215 · Cited by 618
Cited by
Nonlinear magic: multiphoton microscopy in the biosciences
Zipfel, W. R., Williams, R. M., & Webb, W. W. (2003) · Nature Biotechnology · doi:10.1038/nbt899 · Cited by 3,893
Mechanisms of femtosecond laser nanosurgery of cells and tissues
Vogel, A., Noack, J., Hüttman, G., & Paltauf, G. (2005) · Applied Physics B · doi:10.1007/s00340-005-2036-6 · Cited by 1,408
Light at work: The use of optical forces for particle manipulation, sorting, and analysis
Jonáš, A., & Zemánek, P. (2008) · ELECTROPHORESIS · doi:10.1002/elps.200800484 · Cited by 356
Surgical applications of femtosecond lasers
Chung, S. H., & Mazur, E. (2009) · Journal of Biophotonics · doi:10.1002/jbio.200910053 · Cited by 281
Dynamics of femtosecond laser-induced breakdown in water from femtoseconds to microseconds
Schaffer, C. B., Nishimura, N., Glezer, E. N., Kim, A. M.-T., & Mazur, E. (2002) · Optics Express · doi:10.1364/oe.10.000196 · Cited by 258
Metadata
- Authors
- König, K., Riemann, I., & Fritzsche, W.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2001-06-01
- Volume
- 26
- Issue
- 11
- Pages
- 819
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2063407440
- Cited by
- 228
- References
- 1
- FWCI
- 12.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nanodissection of human chromosomes with near-infrared femtosecond laser pulses. https://app.cochat.ai/papers/10.1364/ol.26.000819
- The paper
- König, K., Riemann, I., & Fritzsche, W. (2001). Nanodissection of human chromosomes with near-infrared femtosecond laser pulses. Optics Letters. https://doi.org/10.1364/ol.26.000819
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.