The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Would near-infrared fluorescence signals propagate through large human organs for clinical studies?
Abstract
We predict the capacity of near-infrared fluorescent signals to propagate through human tissue for non-invasive medical imaging. This analysis employs experimental measurements of a biologically relevant local fluorochrome embedded in tissuelike media and predicts the equivalent photon counts expected from breast, lung, brain, and muscle as a function of diameter by use of an analytical solution of the diffusion equation that can take into account large arbitrary geometries. The findings address feasibility issues for clinical studies and are relevant to recent development of near-infrared fluorescent probes and molecular beacons for in vivo applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
A clearer vision for in vivo imaging
Weissleder, R. (2001) · Nature Biotechnology · doi:10.1038/86684 · Cited by 3,839
Self-citation
Cited by
In vivo near-infrared fluorescence imaging
Frangioni, J. V. (2003) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2003.08.007 · Cited by 2,653
New Strategies for Fluorescent Probe Design in Medical Diagnostic Imaging
Kobayashi, H., Ogawa, M., Alford, R., Choyke, P. L., & Urano, Y. (2010) · Chemical Reviews · doi:10.1021/cr900263j · Cited by 2,200
Recent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114
Ntziachristos, V., Bremer, C., & Weissleder, R. (2003) · European Radiology · doi:10.1007/s00330-002-1524-x · Cited by 982
Self-citationFluorescence molecular tomography resolves protease activity in vivo
Ntziachristos, V., Tung, C.-H., Bremer, C., & Weissleder, R. (2002) · Nature Medicine · doi:10.1038/nm729 · Cited by 827
Self-citation
Metadata
- Authors
- Ntziachristos, V., Ripoll, J., & Weissleder, R.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2002-03-01
- Volume
- 27
- Issue
- 5
- Pages
- 333
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2028251682
- Cited by
- 161
- References
- 2
- FWCI
- 11.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Would near-infrared fluorescence signals propagate through large human organs for clinical studies? https://app.cochat.ai/papers/10.1364/ol.27.000333
- The paper
- Ntziachristos, V., Ripoll, J., & Weissleder, R. (2002). Would near-infrared fluorescence signals propagate through large human organs for clinical studies? Optics Letters. https://doi.org/10.1364/ol.27.000333
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.