The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Parametric amplification of few-cycle carrier-envelope phase-stable pulses at 21 μm
Abstract
We demonstrate an optical parametric chirped-pulse amplifier producing infrared 20 fs (3-optical-cycle) pulses with a stable carrier-envelope phase. The amplifier is seeded with self-phase-stabilized pulses obtained by optical rectification of the output of an ultrabroadband Ti:sapphire oscillator. Energies of -80 microJ with a well-suppressed background of parametric superfluorescence and up to 400 microJ with a superfluorescence background are obtained from a two-stage parametric amplifier based on periodically poled LiNbO3 and LiTaO3 crystals. The parametric amplifier is pumped by an optically synchronized 1 kHz, 30 ps, 1053 nm Nd:YLF amplifier seeded by the same Ti:sapphire oscillator.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Attosecond control of electronic processes by intense light fields
Baltuška, A., Udem, T., Uiberacker, M., Hentschel, M., Goulielmakis, E., Gohle, C., Holzwarth, R., Yakovlev, V. S., Scrinzi, A., Hänsch, T. W., et al. (2003) · Nature · doi:10.1038/nature01414 · Cited by 1,653
Self-citation
Cited by
Krausz, F., & Ivanov, M. (2009) · Reviews of Modern Physics · doi:10.1103/revmodphys.81.163 · Cited by 5,468
Self-citationCorkum, P. B., & Krausz, F. (2007) · Nature Physics · doi:10.1038/nphys620 · Cited by 2,151
Self-citationScaling of Wave-Packet Dynamics in an Intense Midinfrared Field
Tate, J., Auguste, T., Muller, H. G., Salières, P., Agostini, P., & DiMauro, L. F. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.013901 · Cited by 611
Macroscopic aspects of attosecond pulse generation
Gaarde, M. B., Tate, J. L., & Schafer, K. J. (2008) · Journal of Physics B: Atomic, Molecular and Optical Physics · doi:10.1088/0953-4075/41/13/132001 · Cited by 398
Ishii, N., Kaneshima, K., Kitano, K., Kanai, T., Watanabe, S., & Itatani, J. (2014) · Nature Communications · doi:10.1038/ncomms4331 · Cited by 228
Self-citation
Metadata
- Authors
- Fuji, T., Ishii, N., Teisset, C. Y., Gu, X., Metzger, T., Baltuska, A., Forget, N., Kaplan, D., Galvanauskas, A., & Krausz, F.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2006-04-15
- Volume
- 31
- Issue
- 8
- Pages
- 1103
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2089482165
- Cited by
- 186
- References
- 1
- FWCI
- 14.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Parametric amplification of few-cycle carrier-envelope phase-stable pulses at 21 μm. https://app.cochat.ai/papers/10.1364/ol.31.001103
- The paper
- Fuji, T., Ishii, N., Teisset, C. Y., Gu, X., Metzger, T., Baltuska, A., Forget, N., Kaplan, D., Galvanauskas, A., & Krausz, F. (2006). Parametric amplification of few-cycle carrier-envelope phase-stable pulses at 21 μm. Optics Letters. https://doi.org/10.1364/ol.31.001103
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.