Discrimination of basal cell carcinoma from normal dermal stroma by quantitative multiphoton imaging
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We performed multiphoton fluorescence (MF) and second-harmonic generation (SHG) imaging on human basal cell carcinoma samples. In the dermis, basal cell carcinomas can be identified by masses of autofluorescent cells with relatively large nuclei and marked peripheral palisading. In the normal dermis, SHG from dermal collagen contributes largely to the multiphoton signal. However, within the cancer stroma, SHG signals diminish and are replaced by autofluorescent signals, indicating that normal collagen structures responsible for SHG have been altered. To better delineate the cancer cells and cancer stroma from the normal dermis, a quantitative MF to SHG index is developed. We demonstrate that this index can be used to differentiate cancer cells and adjacent cancer stroma from the normal dermis. Our work shows that MF and SHG imaging can be an alternative for Mohs' surgery in the real-time guidance of the secure removal of basal cell carcinoma.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Campagnola, P. J., & Loew, L. M. (2003) · Nature Biotechnology · doi:10.1038/nbt894 · Cited by 1,326
Cited by
Second harmonic generation microscopy for quantitative analysis of collagen fibrillar structure
Chen, X., Nadiarynkh, O., Plotnikov, S., & Campagnola, P. J. (2012) · Nature Protocols · doi:10.1038/nprot.2012.009 · Cited by 985
Second Harmonic Generation Imaging Microscopy: Applications to Diseases Diagnostics
Campagnola, P. (2011) · Analytical Chemistry · doi:10.1021/ac1032325 · Cited by 410
Compact and flexible raster scanning multiphoton endoscope capable of imaging unstained tissue
Rivera, D. R., Brown, C. M., Ouzounov, D. G., Pavlova, I., Kobat, D., Webb, W. W., & Xu, C. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1114746108 · Cited by 274
Nadiarnykh, O., LaComb, R. B., Brewer, M. A., & Campagnola, P. J. (2010) · BMC Cancer · doi:10.1186/1471-2407-10-94 · Cited by 264
Morphology and Epidermal Thickness of Normal Skin Imaged by Optical Coherence Tomography
Mogensen, M., Morsy, H. A., Thrane, L., & Jemec, G. B. E. (2008) · Dermatology · doi:10.1159/000118508 · Cited by 183
Metadata
- Authors
- Lin, S.-J., Jee, S.-H., Kuo, C.-J., Wu, R.-J., Lin, W.-C., Chen, J.-S., Liao, Y.-H., Hsu, C.-J., Tsai, T.-F., Chen, Y.-F., & Dong, C.-Y.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2006-08-25
- Volume
- 31
- Issue
- 18
- Pages
- 2756
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W1987719890
- Cited by
- 184
- References
- 1
- FWCI
- 8.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Discrimination of basal cell carcinoma from normal dermal stroma by quantitative multiphoton imaging. https://app.cochat.ai/papers/10.1364/ol.31.002756
- The paper
- Lin, S.-J., Jee, S.-H., Kuo, C.-J., Wu, R.-J., Lin, W.-C., Chen, J.-S., Liao, Y.-H., Hsu, C.-J., Tsai, T.-F., Chen, Y.-F., & Dong, C.-Y. (2006). Discrimination of basal cell carcinoma from normal dermal stroma by quantitative multiphoton imaging. Optics Letters. https://doi.org/10.1364/ol.31.002756
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.