Pulse-resolved measurement of quadrature phase amplitudes of squeezed pulse trains at a repetition rate of 76 MHz
Abstract
We report pulsed homodyne detection of squeezed pulses at a repetition rate of 76 MHz. Measurement of individual pulses, which were interrogated by the correlation coefficient between adjacent pulses, was realized. A homodyne detector was constructed using a low-noise, high-speed operational amplifier; it had a usable bandwidth of 250 MHz. We observed 2.3 dB of squeezing in both the time and frequency domains.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Building a broadband shot noise-limited homodyne detector operating above a few hundred MHz is technically challenging.
“We remark that building a broadband shot noise-limited homodyne detector operating above a few hundred MHz is technically challenging. 37 -39”
From Quantum random number generation (2016) · cites this paper as [37]
The citation lists haven’t been fetched yet
References 13 · Cited by 44
- Authors
- Okubo, R., Hirano, M., Zhang, Y., & Hirano, T.
- Affiliations
- Japan Science and Technology Agency (JP)
- Gakushuin University (JP)
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2008-06-24
- Volume
- 33
- Issue
- 13
- Pages
- 1458
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2014100294
- Cited by
- 44
- References
- 13
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 2 · 2023: 4 · 2022: 2 · 2021: 4 · 2020: 2 · 2019: 2 · 2018: 3 · 2017: 4 · 2016: 2 · 2015: 3 · 2014: 1 · 2013: 2 · 2012: 3
- FWCI
- 4.23
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Optics Letters (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Computer Science › Artificial Intelligence › Quantum Information and Cryptography
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum optics and atomic interactions
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
- Keywords
- squeezed light, high repetition rate, correlation coefficient
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review