Cited by 44Quantum Information and CryptographyQuantum optics and atomic interactionsLaser-Matter Interactions and Applications

Pulse-resolved measurement of quadrature phase amplitudes of squeezed pulse trains at a repetition rate of 76 MHz

Okubo, Ryuhi, Hirano, Mayumi, Zhang, Yun, Hirano, Takuya·2008·Optics Letters

Abstract

We report pulsed homodyne detection of squeezed pulses at a repetition rate of 76 MHz. Measurement of individual pulses, which were interrogated by the correlation coefficient between adjacent pulses, was realized. A homodyne detector was constructed using a low-noise, high-speed operational amplifier; it had a usable bandwidth of 250 MHz. We observed 2.3 dB of squeezing in both the time and frequency domains.

Integrity signals

Registry

Crossref · 10.1364/ol.33.001458

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Building a broadband shot noise-limited homodyne detector operating above a few hundred MHz is technically challenging.

    “We remark that building a broadband shot noise-limited homodyne detector operating above a few hundred MHz is technically challenging. 37 -39”

    From Quantum random number generation (2016) · cites this paper as [37]

The citation lists haven’t been fetched yet

References 13 · Cited by 44

Authors
Okubo, R., Hirano, M., Zhang, Y., & Hirano, T.
Affiliations
  • Japan Science and Technology Agency (JP)
  • Gakushuin University (JP)
Venue
Optics Letters
Published
2008-06-24
Volume
33
Issue
13
Pages
1458
ISSN
  • 0146-9592 (ISSN-L)
  • 1539-4794
OpenAlex
W2014100294
Cited by
44
References
13
Citations by year
2026: 1 · 2025: 1 · 2024: 2 · 2023: 4 · 2022: 2 · 2021: 4 · 2020: 2 · 2019: 2 · 2018: 3 · 2017: 4 · 2016: 2 · 2015: 3 · 2014: 1 · 2013: 2 · 2012: 3
FWCI
4.23
Type
journal article
Language
en
Open access
closed
Locations
  • Optics Letters (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Computer Science › Artificial Intelligence › Quantum Information and Cryptography
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum optics and atomic interactions
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
Keywords
squeezed light, high repetition rate, correlation coefficient

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review