Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 240

The DOI matches its Crossref record.

Bessel beam spectral-domain high-resolution optical coherence tomography with micro-optic axicon providing extended focusing range

Open access
Lee, Kye-Sung, Rolland, Jannick P.·2008·Optics Letters

Abstract

Endoscopic imaging in tubular structures, such as the tracheobronchial tree, could benefit from imaging optics with an extended depth of focus (DOF) to accommodate the varying sizes of tubular structures across patients and along the tree within the same patient. Yet the extended DOF needs to be accomplished without sacrificing resolution while maintaining sufficient sensitivity and speed of imaging. In this Letter, we report on the measured resolution and sensitivity achieved with a custom-made micro-optic axicon lens designed to theoretically achieve an 8 mm DOF. A measured invariant resolution of approximately 8 microm is demonstrated across a 4 mm measured DOF using the micro-optic axicon while achieving an invariant sensitivity of approximately 80 dB with a 25 mW input power. Double-pass Bessel beam spectral-domain optical coherence tomography with an axicon micro-optic lens (i.e., <1 mm in diameter) is, for the first time to our knowledge, demonstrated in a biological sample demonstrating invariant resolution and signal-to-noise ratio across a 4 mm measured DOF, which is compared to Gaussian beam imaging.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/ol.33.001696

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 240

Metadata

Authors
Lee, K.-S., & Rolland, J. P.
Venue
Optics Letters
Published
2008-07-24
Volume
33
Issue
15
Pages
1696
ISSN
  • 0146-9592 (ISSN-L)
  • 1539-4794
OpenAlex
W2144515995
Cited by
240
References
0
FWCI
6.18
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bessel beam spectral-domain high-resolution optical coherence tomography with micro-optic axicon providing extended focusing range. https://app.cochat.ai/papers/10.1364/ol.33.001696
The paper
Lee, K.-S., & Rolland, J. P. (2008). Bessel beam spectral-domain high-resolution optical coherence tomography with micro-optic axicon providing extended focusing range. Optics Letters. https://doi.org/10.1364/ol.33.001696

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.