The DOI matches its Crossref record.
Wavelength-tunable microbolometers with metamaterial absorbers
Abstract
Microbolometers are modified by metallic resonant absorber elements, leading to an enhanced responsivity at selectable wavelengths. The dissipative energy absorption of tailored metamaterials allows for engineering the response of conventional bolometer microbridges. The absorption peak position and height are determined by the geometry of the metamaterial. Square-shaped metal/dielectric/metal stacks as absorber elements show spectral resonances at wavelengths between 4.8 and 7.0 microm in accordance with numerical simulations. Total peak absorptions of 0.8 are obtained. The metamaterial modified bolometers are suitable for multispectral thermal imaging systems in the mid-IR and terahertz regime.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Water‐Resonator‐Based Metasurface: An Ultrabroadband and Near‐Unity Absorption
Song, Q., Zhang, W., Wu, P. C., Zhu, W., Shen, Z. X., Chong, P. H. J., Liang, Q. X., Yang, Z. C., Hao, Y. L., Cai, H., et al. (2017) · Advanced Optical Materials · doi:10.1002/adom.201601103 · Cited by 156
Metadata
- Authors
- Maier, T., & Brückl, H.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2009-09-30
- Volume
- 34
- Issue
- 19
- Pages
- 3012
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2138021594
- Cited by
- 199
- References
- 0
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wavelength-tunable microbolometers with metamaterial absorbers. https://app.cochat.ai/papers/10.1364/ol.34.003012
- The paper
- Maier, T., & Brückl, H. (2009). Wavelength-tunable microbolometers with metamaterial absorbers. Optics Letters. https://doi.org/10.1364/ol.34.003012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.