Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 177

The DOI matches its Crossref record.

Generation of 50 fs, 50 mJ pulses at 1 kHz using hollow-fiber pulse compression

Bohman, Samuel, Suda, Akira, Kanai, Tsuneto, Yamaguchi, Shigeru, Midorikawa, Katsumi · 2010 · Optics Letters

Abstract

We demonstrate methods to increase the energy incident on hollow fibers for spectral broadening by self-phase modulation. We used chirped pulses for spectral broadening, lowering the optical intensity to avoid ionization of the gaseous medium. We also used helium as a nonlinear medium and demonstrated the generation of 5.0fs, 5.0mJ pulses at a repetition rate of 1kHz using a pressure gradient hollow-fiber pulse compressor.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/ol.35.001887

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 177

Metadata

Authors
Bohman, S., Suda, A., Kanai, T., Yamaguchi, S., & Midorikawa, K.
Venue
Optics Letters
Published
2010-05-27
Volume
35
Issue
11
Pages
1887
ISSN
  • 0146-9592 (ISSN-L)
  • 1539-4794
OpenAlex
W1863839614
Cited by
177
References
0
FWCI
14.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Generation of 50 fs, 50 mJ pulses at 1 kHz using hollow-fiber pulse compression. https://app.cochat.ai/papers/10.1364/ol.35.001887
The paper
Bohman, S., Suda, A., Kanai, T., Yamaguchi, S., & Midorikawa, K. (2010). Generation of 50 fs, 50 mJ pulses at 1 kHz using hollow-fiber pulse compression. Optics Letters. https://doi.org/10.1364/ol.35.001887

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.