Direct-comb molecular spectroscopy with accurate, resolved comb teeth over 43 THz
Abstract
We demonstrate a dual-comb spectrometer using stabilized frequency combs spanning 177 to 220 THz (1360 to 1690 nm) in the near infrared. Comb-tooth-resolved measurements of amplitude and phase generate over 4×10(5) individually resolved spectral elements at 100 MHz point spacing and kilohertz-level resolution and accuracy. The signal-to-noise ratio is 100 to 3000 per comb tooth. Doppler-broadened phase and amplitude spectra of CO(2), CH(4), C(2)H(2), and H(2)O in a 30 m multipass cell agree with established spectral parameters, achieving high-resolution measurements with optical bandwidth generally associated with blackbody sources.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Most ASOPS THz-TDS techniques use IFG, sum-frequency generation, or two-photon absorption of pulsed lasers as a trigger for signal accumulation.
“Most ASOPS THz-TDS techniques use IFG, sum-frequency generation, or twophoton absorption of pulsed lasers as a trigger for signal accumulation [3,11,12,18,31].”
From Jitter correction for asynchronous optical sampling terahertz spectroscopy using free-running pulsed lasers (2023) · cites this paper as [31]
No citation lists for this paper
No citation lists for this paper yet — checked again daily.
References 13 · Cited by 145
- Authors
- Zolot, A. M., Giorgetta, F. R., Baumann, E., Nicholson, J. W., Swann, W. C., Coddington, I., & Newbury, N. R.
- Affiliations
- National Institute of Standards and Technology (US)
- Venue
- Optics Letters
- Publisher
- The Optical Society
- Published
- 2012-02-10
- Volume
- 37
- Issue
- 4
- Pages
- 638
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2009882629
- Cited by
- 145
- References
- 13
- Citations by year
- 2026: 3 · 2025: 6 · 2024: 6 · 2023: 8 · 2022: 5 · 2021: 15 · 2020: 13 · 2019: 8 · 2018: 12 · 2017: 8 · 2016: 20 · 2015: 14 · 2014: 11 · 2013: 11 · 2012: 5
- FWCI
- 5.80
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Optics Letters (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Swiss National Science Foundation (SNSF) (PBNEP2-127797)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Spectroscopy and Laser Applications
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Fiber Laser Technologies
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
- Keywords
- dual-comb spectroscopy, frequency combs, comb teeth, high-resolution spectroscopy, Doppler broadening, carbon dioxide, methane, acetylene, water vapor, multi-pass cell, near-infrared spectroscopy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review