Doppler-stabilized fiber link with 6 dB noise improvement below the classical limit
Open accessAbstract
It is known that temperature variations and acoustic noise affect ultrastable frequency dissemination along optical fiber. Active stabilization techniques are adopted to compensate for the fiber-induced phase noise. However, despite this compensation, the ultimate link performances are limited by the delay-unsuppressed noise that is related to the propagation delay of the light in the fiber. We demonstrate a post-processing approach which enables us to overcome this limit. We implement a subtraction algorithm between the optical signal delivered at the remote link end and the round-trip signal. In this way, a 6 dB improvement beyond the delay-unsuppressed noise is obtained. We confirm the prediction with experimental data obtained on a 47 km metropolitan fiber link and propose how to extend this method for frequency dissemination.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Phase-coherent telecom fibre links are extremely powerful tools for frequency dissemination on a continental scale.
“Complemented by phase-coherent telecom fibre links9101112 as extremely powerful tools for frequency dissemination on a continental scale”
From A clock network for geodesy and fundamental science (2016) · cites this paper as [11]
The passage labeled Abstract (p. 2) calls optical fiber links a key tool for frequency dissemination and describes coherent links using standard telecom fiber. But the reported experiment used a 47 km metropolitan link (Abstract, pp. 1, 3); our copy does not establish frequency dissemination on a continental scale. (LLM, conf=0.84)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 24 · Cited by 23
Research works printed but not linked: 6
- [4]F. Levi, R. Ambrosini, D. Calonico, C. E. Calosso, C. Clivati, G. A. Costanzo, P. De Natale, D. Mazzotti, M. Frittelli, G. Galzerano, A. Mura, D. Sutyrin, G. M. Tino, M. E. Zucco, N. Poli, in Proceedings of the Joint UFFC, EFTF and PFM Symposium (2013) .
- [5]L. ´ Sliwczy´ nski, P. Krehlik, L. Buczek, M. Lipi´ nski, IEEE Trans. Instr. Meas. 61 , 2573 (2012).
- [6]M. Fujieda, M. Kumagai, S. Nagano, IEEE Trans. Ultrason. Ferroel. Freq. Contr. 57 , 168 (2010).
- [14]J.-F. Clich´ e, B. Shillue, IEEE Control Sys. Mag. 26 , 19 (2006).
- [16]C. E. Calosso, in Proceedings of the Joint UFFC, EFTF and PFM Symposium (2013), p. 747 .
- [18]C. Clivati, D. Calonico, C. E. Calosso, G. A. Costanzo, F. Levi, A. Mura, A. Godone, IEEE Trans. Ultrason. Ferroelectr. Freq. Contr. 58 , 2582 (2011).
- Authors
- Calosso, C. E., Bertacco, E. K., Calonico, D., Clivati, C., Costanzo, G. A., Frittelli, M., Levi, F., Micalizio, S., Mura, A., & Godone, A.
- Affiliations
- Istituto Nazionale di Ricerca Metrologica (IT)
- ORCID
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2015-01-07
- Volume
- 40
- Issue
- 2
- Pages
- 131
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W1760268901
- Cited by
- 23
- References
- 24
- Citations by year
- 2025: 2 · 2024: 2 · 2023: 3 · 2022: 4 · 2021: 2 · 2019: 1 · 2018: 1 · 2017: 2 · 2016: 3 · 2015: 3
- FWCI
- 1.52
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Locations
- Optics Letters (publishedVersion)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- CINECA IRIS Institutional Research Information System (IRIS Istituto Nazionale di Ricerca Metrologica) (submittedVersion, other-oa)
- PORTO@Iris (submittedVersion, other-oa)
- PORTO Publications Open Repository TOrino (Politecnico di Torino) (submittedVersion, other-oa)
- arXiv (Cornell University)
- Funders
- Compagnia di San Paolo
- European Association of National Metrology Institutes
- European Commission
- Ministero dell’Istruzione, dell’Università e della Ricerca
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Photonic Communication Systems
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Optical Network Technologies
- Keywords
- fiber links, active stabilization, frequency dissemination
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review