The DOI matches its Crossref record.
Novel geometry for single-mode scanning of tunable lasers
Abstract
We describe a geometry that allows for the single-mode scanning of lasers that use a diffraction grating as the dispersive element. It is observed that under the right conditions a rotation of the tuning element can provide changes simultaneously in cavity length and diffraction angle that exactly match the requirements needed for continuous single-mode scanning. As a case study, the method is applied to the grazing-incidence pulsed dye laser.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rare-earth-doped materials for applications in quantum information storage and signal processing
Thiel, C. W., Böttger, T., & Cone, R. L. (2011) · Journal of Luminescence · doi:10.1016/j.jlumin.2010.12.015 · Cited by 420
Li, M., Chang, L., Wu, L., Staffa, J., Ling, J., Javid, U. A., Xue, S., He, Y., Lopez-rios, R., Morin, T. J., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-33101-6 · Cited by 172
Metadata
- Authors
- Liu, K., & Littman, M. G.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 1981-03-01
- Volume
- 6
- Issue
- 3
- Pages
- 117
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2163247994
- Cited by
- 334
- References
- 0
- FWCI
- 3.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Novel geometry for single-mode scanning of tunable lasers. https://app.cochat.ai/papers/10.1364/ol.6.000117
- The paper
- Liu, K., & Littman, M. G. (1981). Novel geometry for single-mode scanning of tunable lasers. Optics Letters. https://doi.org/10.1364/ol.6.000117
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.