The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Quantitative measurement of attenuation coefficients of weakly scattering media using optical coherence tomography
Open accessAbstract
From calibrated, weakly scattering tissue phantoms (2-6 mm-1), we extract the attenuation coefficient with an accuracy of 0.8 mm-1 from OCT data in the clinically relevant 'fixed focus' geometry. The data are analyzed using a single scattering model and a recently developed description of the confocal point spread function (PSF). We verify the validity of the single scattering model by a quantitative comparison with a multiple scattering model, and validate the use of the PSF on the calibrated samples. Implementation of this model for existing OCT systems will be straightforward. Localized quantitative measurement of the attenuation coefficient of different tissues can significantly improve the clinical value of OCT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Practical Statistics for Medical Research
Altman, D. G. (1990) · doi:10.1201/9780429258589 · Cited by 10,668
Cited by
Vermeer, K. A., Mo, J., Weda, J. J. A., Lemij, H. G., & de Boer, J. F. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.000322 · Cited by 373
Chang, S., & Bowden, A. K. (2019) · Journal of Biomedical Optics · doi:10.1117/1.jbo.24.9.090901 · Cited by 99
Metadata
- Authors
- Faber, D. J., van der Meer, F. J., Aalders, M. C. G., & van Leeuwen, T. G.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2004
- Volume
- 12
- Issue
- 19
- Pages
- 4353
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2052348811
- Cited by
- 299
- References
- 1
- FWCI
- 2.78
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative measurement of attenuation coefficients of weakly scattering media using optical coherence tomography. https://app.cochat.ai/papers/10.1364/opex.12.004353
- The paper
- Faber, D. J., van der Meer, F. J., Aalders, M. C. G., & van Leeuwen, T. G. (2004). Quantitative measurement of attenuation coefficients of weakly scattering media using optical coherence tomography. Optics Express. https://doi.org/10.1364/opex.12.004353
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.