Influence of a fat layer on the near infrared spectra of human muscle: quantitative analysis based on two-layered Monte Carlo simulations and phantom experiments
Open accessThe DOI matches its Crossref record.
Abstract
The influence of fat thickness on the diffuse reflectance spectra of muscle in the near infrared (NIR) region is studied by Monte Carlo simulations of a two-layer structure and with phantom experiments. A polynomial relationship was established between the fat thickness and the detected diffuse reflectance. The influence of a range of optical coefficients (absorption and reduced scattering) for fat and muscle over the known range of human physiological values was also investigated. Subject-to-subject variation in the fat optical coefficients and thickness can be ignored if the fat thickness is less than 5 mm. A method was proposed to correct the fat thickness influence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
“The influence of adipose tissue thickness on the NIR spectra of human muscle was studied by Monte Carlo simulations of a two-layer structure and with phantom experiments.(41) The study suggested that subject-to-subject variation in the fat optical coefficients and thickness can be ignored if the fat thick-”
Feldmann, A., Schmitz, R. W., & Erlacher, D. (2019) · Journal of Biomedical Optics · doi:10.1117/1.jbo.24.11.115001 · Cited by 203
Southern, W. M., Ryan, T. E., Reynolds, M. A., & McCully, K. (2014) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2013-0347 · Cited by 80
Asymmetry of quadriceps muscle oxygenation during elite short-track speed skating
HESFORD, C. M., LAING, S. J., CARDINALE, M., & COOPER, C. E. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31822f8942 · Cited by 63
“Photon migration and Monte Carlo simulations suggest a maximum penetration depth of half the distance between emitter and detector, that is, 20 mm for this device (7,38); for a review of this, see Hamaoka et al.”
BackgroundNiemeijer, V. M., Jansen, J. P., van Dijk, T., Spee, R. F., Meijer, E. J., Kemps, H. M. C., & Wijn, P. F. F. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa5dd5 · Cited by 61
“In contrast to suggestions by other authors (Yang et al 2005), the in vitro experiments show that even a minimal ATT of 1 mm is expected to influence StO 2 measurements to a great degree.”
Metadata
- Authors
- Yang, Y., Soyemi, O. O., Landry, M. R., & Soller, B. R.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2005
- Volume
- 13
- Issue
- 5
- Pages
- 1570
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2009876382
- Cited by
- 47
- References
- 0
- FWCI
- 2.38
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.