The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Direct imaging of a digital-micromirror device for configurable microscopic optical potentials
Open accessAbstract
Programable spatial light modulators (SLMs) have significantly advanced the configurable optical trapping of particles. Typically, these devices are utilized in the Fourier plane of an optical system, but direct imaging of an amplitude pattern can potentially result in increased simplicity and computational speed. Here we demonstrate high-resolution direct imaging of a digital micromirror device (DMD) at high numerical apertures (NA), which we apply to the optical trapping of a Bose-Einstein condensate (BEC). We utilise a (1200 x 1920) pixel DMD and commercially available 0.45 NA microscope objectives, finding that atoms confined in a hybrid optical/magnetic or all-optical potential can be patterned using repulsive blue-detuned (532 nm) light with 630(10) nm full-width at half-maximum (FWHM) resolution, within 5% of the diffraction limit. The result is near arbitrary control of the density the BEC without the need for expensive custom optics. We also introduce the technique of time-averaged DMD potentials, demonstrating the ability to produce multiple grayscale levels with minimal heating of the atomic cloud, by utilising the high switching speed (20 kHz maximum) of the DMD. These techniques will enable the realization and control of diverse optical potentials for superfluid dynamics and atomtronics applications with quantum gases. The performance of this system in a direct imaging configuration has wider application for optical trapping at non-trivial NAs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Exploring the many-body localization transition in two dimensions
Choi, J.-Y., Hild, S., Zeiher, J., Schauß, P., Rubio-Abadal, A., Yefsah, T., Khemani, V., Huse, D. A., Bloch, I., & Gross, C. (2016) · Science · doi:10.1126/science.aaf8834 · Cited by 979
Cited by
Forbes, A., de Oliveira, M., & Dennis, M. R. (2021) · Nature Photonics · doi:10.1038/s41566-021-00780-4 · Cited by 1,367
Optical trapping gets structure: Structured light for advanced optical manipulation
Otte, E., & Denz, C. (2020) · Applied Physics Reviews · doi:10.1063/5.0013276 · Cited by 258
Metadata
- Authors
- Gauthier, G., Lenton, I., McKay Parry, N., Baker, M., Davis, M. J., Rubinsztein-Dunlop, H., & Neely, T. W.
- Venue
- Optica
- Publisher
- Optica Publishing Group
- Published
- 2016-10-12
- Volume
- 3
- Issue
- 10
- Pages
- 1136
- ISSN
- 2334-2536 (ISSN-L)
- OpenAlex
- W2530278545
- Cited by
- 199
- References
- 1
- FWCI
- 8.41
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Direct imaging of a digital-micromirror device for configurable microscopic optical potentials. https://app.cochat.ai/papers/10.1364/optica.3.001136
- The paper
- Gauthier, G., Lenton, I., McKay Parry, N., Baker, M., Davis, M. J., Rubinsztein-Dunlop, H., & Neely, T. W. (2016). Direct imaging of a digital-micromirror device for configurable microscopic optical potentials. Optica. https://doi.org/10.1364/optica.3.001136
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.