The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Modeling and Measuring the Effect of Refraction on the Depth Resolution of Confocal Raman Microscopy
Abstract
A simple ray-tracing analysis has been used to predict the effect of refraction at the sample/air interface, on the depth resolution of confocal Raman microscopy. This analysis applies to the “z-scanning”, or “optical sectioning”, approach to obtaining depth profiles, where the laser beam is incident normal to the sample surface, and spectra are recorded sequentially as the focus is moved deeper into the material. It is shown that when a “dry” metallurgical objective (the most common configuration for commercial Raman microscopes) is used, both the position and the depth of focus increase dramatically as the beam is focused deeper into the sample. It quickly becomes impossible to obtain “pure” spectra of thin layers that are buried more than a few micrometers below the air interface. Equations are presented which model the intensity response expected when focusing through a coating into a substrate. The model requires knowledge of the sample refractive index, the numerical aperture, and the laser beam intensity distribution at the limiting aperture, of the objective. Given these values, one can predict the substrate Raman intensity as a function of the nominal focal point within the sample. For a 36 μm coating on a thick substrate, we predict that even for a perfectly sharp interface (<<1 μm), substrate bands rise slowly (over an apparent distance of 10 μm or more), and are strong when the focus is apparently only ∼ 18 μm below the air/coating interface. This prediction was confirmed through experimental observation. The model was also used to analyze literature data that had been interpreted previously as showing interfacial diffusion in polymer laminates. The model correctly reproduced the main features of the observed data without invoking interfacial penetration—the optical aberrations alone accounted for almost all the observed broadening and the fact that the apparent thickness of the buried layer is also distorted. It was concluded that, with the use of this illumination geometry, it is very difficult to detect or quantify interfacial broadening unless it occurs on a very large scale indeed (tens of micrometers). It is concluded that ‘optical sectioning’ cannot be recommended for quantitative depth profiling at significant depths using metallurgical objectives. The optimum practical solution is to cut a cross section and map laterally across the sample, thereby utilizing and maintaining the excellent (lateral) resolution of the Raman microprobe. An alternative solution is to use an immersion objective to minimize refraction at the sample surface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analytical Applications of Raman Spectroscopy
Pelletier, M. J. (1999) · Medical Entomology and Zoology · Cited by 439
Confocal Raman Microspectroscopy Using a Stigmatic Spectrograph and CCD Detector
Williams, K. P. J., Pitt, G. D., Batchelder, D. N., & Kip, B. J. (1994) · Applied Spectroscopy · doi:10.1366/0003702944028407 · Cited by 160
Description and performance of a highly sensitive confocal Raman microspectrometer
Puppels, G. J., Colier, W. N. J. M., Olminkhof, J. H. F., Otto, C., de Mul, F. F. M., & Greve, J. (1991) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1250220405 · Cited by 132
Rapid Analysis of Raman Image Data Using Two-Way Multivariate Curve Resolution
Andrew, J. J., & Hancewicz, T. M. (1998) · Applied Spectroscopy · doi:10.1366/0003702981944526 · Cited by 114
Raman Imaging of Heterogeneous Polymers: A Comparison of Global versus Point Illumination
Markwort, L., Kip, B. J., Silva, E. D., & Roussel, B. (1995) · Applied Spectroscopy · doi:10.1366/0003702953965452 · Cited by 85
Hajatdoost, S., & Yarwood, J. (1996) · Applied Spectroscopy · doi:10.1366/0003702963905961 · Cited by 58
Everall, N. J., Davis, K. L., Owen, H., Pelletier, M. J., & Slater, J. (1996) · Applied Spectroscopy · doi:10.1366/0003702963906258 · Cited by 32
Self-citation
Cited by
Raman Microspectrometry Applied to the Study of Electrode Materials for Lithium Batteries
Baddour-Hadjean, R., & Pereira-Ramos, J.-P. (2010) · Chemical Reviews · doi:10.1021/cr800344k · Cited by 749
Raman spectroscopy in pharmaceutical product design
Paudel, A., Raijada, D., & Rantanen, J. (2015) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.04.003 · Cited by 302
The potential of Raman microscopy and Raman imaging in plant research
Gierlinger, N., & Schwanninger, M. (2007) · Journal of Spectroscopy · doi:10.1155/2007/498206 · Cited by 273
Sarua, A., Ji, H., Kuball, M., Uren, M. J., Martin, T., Hilton, K. P., & Balmer, R. S. (2006) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2006.882274 · Cited by 267
Metadata
- Authors
- Everall, N. J.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2000-06
- Volume
- 54
- Issue
- 6
- Pages
- 773-782
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W2064362324
- Cited by
- 339
- References
- 7
- FWCI
- 12.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Modeling and Measuring the Effect of Refraction on the Depth Resolution of Confocal Raman Microscopy. https://app.cochat.ai/papers/10.1366/0003702001950382
- The paper
- Everall, N. J. (2000). Modeling and Measuring the Effect of Refraction on the Depth Resolution of Confocal Raman Microscopy. Applied Spectroscopy. https://doi.org/10.1366/0003702001950382
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.