The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Near-Infrared Raman Spectroscopy for in vivo Detection of Cervical Precancers
Abstract
This study evaluates the potential of near-infrared Raman spectroscopy for in vivo detection of squamous dysplasia, a precursor to cervical cancer. A pilot clinical trial was carried out at three clinical sites. Raman spectra were measured from one colposcopically normal and one abnormal area of the cervix. These sites were then biopsied and submitted for routine histologic analysis. Twentyfour evaluable measurements were made in vivo in 13 patients. Cervical tissue Raman spectra contain peaks in the vicinity of 1070, 1180, 1195, 1210, 1245, 1330, 1400, 1454, 1505, 1555, 1656, and 1760 cm−1. The ratio of intensities at 1454 to 1656 cm−1 is greater for squamous dysplasia than all other tissue types, while the ratio of intensities at 1330 to 1454 cm−1 is lower for samples with squamous dysplasia than all other tissue types. A simple algorithm based on these two intensity ratios separates high-grade squamous dysplasia from all others, misclassifying only one sample. Spectra measured in vivo resemble those measured in vitro. Cervical epithelial cells may contribute to tissue spectra at 1330 cm−1, a region associated with DNA. In contrast, epithelial cells probably do not contribute to tissue spectra at 1454 cm−1, a region associated with collagen and phospholipids.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smoothing and Differentiation of Data by Simplified Least Squares Procedures.
Savitzky, A., & Golay, M. J. E. (1964) · Analytical Chemistry · doi:10.1021/ac60214a047 · Cited by 21,904
Cited by
Raman Spectroscopy of Biological Tissues
Movasaghi, Z., Rehman, S., & Rehman, I. U. (2007) · Applied Spectroscopy Reviews · doi:10.1080/05704920701551530 · Cited by 2,518
Fourier Transform Infrared (FTIR) Spectroscopy of Biological Tissues
Movasaghi, Z., Rehman, S., & ur Rehman, D. I. (2008) · Applied Spectroscopy Reviews · doi:10.1080/05704920701829043 · Cited by 1,916
Localized surface plasmon resonance: Nanostructures, bioassays and biosensing—A review
Petryayeva, E., & Krull, U. J. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.08.020 · Cited by 1,379
Metabolomics: Current analytical platforms and methodologies
(2005) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2004.11.021 · Cited by 1,192
Near‐infrared Raman spectroscopy for optical diagnosis of lung cancer
Huang, Z., McWilliams, A., Lui, H., McLean, D. I., Lam, S., & Zeng, H. (2003) · International Journal of Cancer · doi:10.1002/ijc.11500 · Cited by 821
Metadata
- Authors
- Utzinger, U., Heintzelman, D. L., Mahadevan-Jansen, A., Malpica, A., Follen, M., & Richards-Kortum, R.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2001-08
- Volume
- 55
- Issue
- 8
- Pages
- 955-959
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W1985900918
- Cited by
- 251
- References
- 1
- FWCI
- 5.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Near-Infrared Raman Spectroscopy for in vivo Detection of Cervical Precancers. https://app.cochat.ai/papers/10.1366/0003702011953018
- The paper
- Utzinger, U., Heintzelman, D. L., Mahadevan-Jansen, A., Malpica, A., Follen, M., & Richards-Kortum, R. (2001). Near-Infrared Raman Spectroscopy for in vivo Detection of Cervical Precancers. Applied Spectroscopy. https://doi.org/10.1366/0003702011953018
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.