The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Absorption of Water by Room-Temperature Ionic Liquids: Effect of Anions on Concentration and State of Water
Abstract
Near-infrared (NIR) spectrometry was successfully used for the noninvasive and in situ determination of concentrations and structure of water absorbed by room-temperature ionic liquids (RTILs). It was found that RTILs based on 1-butyl-3-methylimidazolium, namely, [BuMIm]+[BF 4]−, [BuMIm]+[bis((trifluoromethyl)sulfonyl)amide, or Tf 2 N]− and [BuMIm]+[PF 6]−, are hydroscopic and can quickly absorb water when they are exposed to air. Absorbed water interacts with the anions of the RTILs, and these interactions lead to changes in the structure of water. Among the RTILs studied, [BF 4]− provides the strongest interactions and [PF 6]− the weakest. In 24 hours, [BuMIm]+[BF 4]− can absorb up to 0.320 M of water, whereas [BuMIm]+[PF 6]− can only absorb 8.3 × 10−2 M of water. It seems that higher amounts of water can be absorbed when the anion of the RTIL can strongly interact and hence stabilize absorbed water molecules by forming hydrogen bonds with them or inducing hydrogen bonds among water molecules. More importantly, the NIR technique can be sensitively used for the noninvasive, in situ determination of absorbed water in RTILs, without any pretreatment, and at limits of detection as low as 3.20 × 10−3 M.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cammarata, L., Kazarian, S. G., Salter, P. A., & Welton, T. (2001) · Physical Chemistry Chemical Physics · doi:10.1039/b106900d · Cited by 1,441
Cited by
Mele, A., Tran, C. D., & De Paoli Lacerda, S. H. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200351783 · Cited by 432
Self-citationUnderstanding Ionic Liquids through Atomistic and Coarse-Grained Molecular Dynamics Simulations
Wang, Y., Jiang, W., Yan, T., & Voth, G. A. (2007) · Accounts of Chemical Research · doi:10.1021/ar700160p · Cited by 331
Tran, C. D., Duri, S., Delneri, A., & Franko, M. (2013) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2013.02.046 · Cited by 121
Self-citationIonic liquids in enzymatic catalysis and biochemical methods of analysis: Capabilities and prospects
Muginova, S. V., Galimova, A. Z., Polyakov, A. E., & Shekhovtsova, T. N. (2010) · Journal of Analytical Chemistry · doi:10.1134/s1061934810040027 · Cited by 36
Metadata
- Authors
- Tran, C. D., De Paoli Lacerda, S. H., & Oliveira, D.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2003-02
- Volume
- 57
- Issue
- 2
- Pages
- 152-157
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W2102214452
- Cited by
- 278
- References
- 1
- FWCI
- 5.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Absorption of Water by Room-Temperature Ionic Liquids: Effect of Anions on Concentration and State of Water. https://app.cochat.ai/papers/10.1366/000370203321535051
- The paper
- Tran, C. D., De Paoli Lacerda, S. H., & Oliveira, D. (2003). Absorption of Water by Room-Temperature Ionic Liquids: Effect of Anions on Concentration and State of Water. Applied Spectroscopy. https://doi.org/10.1366/000370203321535051
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.