Gas-Phase Databases for Quantitative Infrared Spectroscopy
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
The National Institute of Standards and Technology (NIST) and the Pacific Northwest National Laboratory (PNNL) are each creating quantitative databases containing the vapor-phase infrared spectra of pure chemicals. The digital databases have been created with both laboratory and remote-sensing applications in mind. A spectral resolution of ≈0.1 cm−1 was selected to avoid degrading sharp spectral features, while also realizing that atmospheric broadening typically limits line widths to 0.1 cm−1. Calculated positional (wavenumber, cm−1) uncertainty is ≤0.005 cm−1, while the 1σ statistical uncertainty in absorbance values is <2% for most compounds. The latter was achieved by measuring multiple (typically ≥9) path length–concentration burdens and fitting a weighted Beer's law plot to each wavenumber channel. The two databases include different classes of compounds and were compared using 12 samples. Though these 12 samples span a range of polarities, absorption strengths, and vapor pressures, the data agree to within experimental uncertainties with only one exception.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction to Error Analysis
Taylor, J. R. (1982) · Medical Entomology and Zoology · Cited by 2,807
An Introduction to Error Analysis: The Study of Uncertainties in Physical Measurements
Taylor, J. R., & Thompson, W. (1998) · Physics Today · doi:10.1063/1.882103 · Cited by 2,734
THE HITRAN MOLECULAR SPECTROSCOPIC DATABASE AND HAWKS (HITRAN ATMOSPHERIC WORKSTATION): 1996 EDITION
ROTHMAN, L. S., RINSLAND, C. P., GOLDMAN, A., MASSIE, S. T., EDWARDS, D. P., FLAUD, J.-M., PERRIN, A., CAMY-PEYRET, C., DANA, V., MANDIN, J.-Y., et al. (1998) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/s0022-4073(98)00078-8 · Cited by 1,925
The Aldrich library of FT-IR spectra
Pouchert, C. J. (1985) · Aldrich Chemical Co. eBooks · Cited by 734
Introductory Fourier Transform Spectroscopy
(1972) · Elsevier eBooks · doi:10.1016/b978-0-12-085150-8.x5001-3 · Cited by 591
The 1997 spectroscopic GEISA databank
Jacquinet-Husson, N., Arié, E., Ballard, J., Barbe, A., Bjoraker, G. L., Bonnet, B., Brown, L. R., Camy-Peyret, C., Champion, J. P., Chédin, A., et al. (1999) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/s0022-4073(98)00111-3 · Cited by 281
Auxiliary computation for Fourier spectrometry
Mertz, L. (1967) · Infrared Physics · doi:10.1016/0020-0891(67)90026-7 · Cited by 205
The NIST quantitative infrared database
Chu, P. M., Guenther, F. R., Rhoderick, G. C., & Lafferty, W. J. (1999) · Journal of Research of the National Institute of Standards and Technology · doi:10.6028/jres.104.004 · Cited by 167
Self-citationManagement and study of spectroscopic information: The GEISA program
Jacquinet-Husson, N., Bonnet, B., Scott, N. A., & Chédin, A. (1992) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/0022-4073(92)90116-l · Cited by 96
Ballard, J., Knight, R. J., Newnham, D. A., Auwera, J. V., Herman, M., Lonardo, G. D., Masciarelli, G., Nicolaisen, F. M., Beukes, J. A., Christensen, L. K., et al. (2000) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/s0022-4073(99)00211-3 · Cited by 71
High resolution and the accurate measurement of intensities
Johns, J. W. C. (1987) · Microchimica Acta · doi:10.1007/bf01201689 · Cited by 69
Ghosts and artifacts in Fourier-transform spectrometry
Learner, R. C. M., Thorne, A. P., & Brault, J. W. (1996) · Applied Optics · doi:10.1364/ao.35.002947 · Cited by 59
Phase correction of emission line Fourier transform spectra
Learner, R. C. M., Brault, J. W., Abrams, M. C., Thorne, A. P., & Wynne-Jones, I. (1995) · Journal of the Optical Society of America A · doi:10.1364/josaa.12.002165 · Cited by 46
Cited by
The HITRAN2016 molecular spectroscopic database
Gordon, I. E., Rothman, L. S., Hill, C., Kochanov, R. V., Tan, Y., Bernath, P. F., Birk, M., Boudon, V., Campargue, A., Chance, K. V., et al. (2017) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2017.06.038 · Cited by 7,721
“…298–323 760 0.112 N 2 Johnson et al. (2010) [519] Furfuryl alcohol 98–00–0 550–7300 298–323 760 0.112 N 2 Sharpe et al. (2004) [314] Geraniol 106–24–1 60 0–650 0 323 760 0.112 N 2 Johnson et al. (2010) [519] Glycolaldehyde 141–46–8 570–6500 298–332 760 0.112 N 2 Johnson et al. (2010) [519]…”
InfluentialSelf-citationThe HITRAN 2008 molecular spectroscopic database
Rothman, L. S., Gordon, I. E., Barbe, A., Benner, D. C., Bernath, P. F., Birk, M., Boudon, V., Brown, L. R., Campargue, A., Champion, J.-P., et al. (2009) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2009.02.013 · Cited by 3,335
The HITRAN2012 molecular spectroscopic database
Rothman, L. S., Gordon, I. E., Babikov, Y., Barbe, A., Chris Benner, D., Bernath, P. F., Birk, M., Bizzocchi, L., Boudon, V., Brown, L. R., et al. (2013) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2013.07.002 · Cited by 3,255
The HITRAN2020 molecular spectroscopic database
Gordon, I. E., Rothman, L. S., Hargreaves, R. J., Hashemi, R., Karlovets, E. V., Skinner, F. M., Conway, E. K., Hill, C., Kochanov, R. V., Tan, Y., et al. (2022) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2021.107949 · Cited by 2,600
Hodgkinson, J., & Tatam, R. P. (2013) · Measurement Science and Technology · doi:10.1088/0957-0233/24/1/012004 · Cited by 1,745
Metadata
- Authors
- Sharpe, S. W., Johnson, T. J., Sams, R. L., Chu, P. M., Rhoderick, G. C., & Johnson, P. A.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2004-12
- Volume
- 58
- Issue
- 12
- Pages
- 1452-1461
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W2090437031
- Cited by
- 948
- References
- 13
- FWCI
- 6.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.